distillation

  • $17,995.00

    Polyscience 8HP Heavy Duty Air Cooled 3 Phase Chiller will handle different tasks - 50L roto rating. When precision liquid cooling matters, go with Polyscience cooling solutions.
    • DuraChill® Chillers 2HP and up are not available outside of the United States
    • High capacity cooling for plasma torch cutting, machine tool hydraulics, high powered lasers, and other high heat generating processes and equipment
    • Displays temperature and pressure or flow rate simultaneously
    • User-adjustable temperature, pressure, and flow rate alarms
    • Simple operation and maintenance
    • Wide variety of options available
      To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing.
  • $14,285.00

    Polyscience 3HP Heavy Duty Durachill will handle numerous tasks. Air cooled with simple operation and maintenance. When precision liquid cooling matters, go with Polyscience cooling solutions.
    • DuraChill® Chillers 2HP and up are not available outside of the United States
    • High capacity cooling for plasma torch cutting, machine tool hydraulics, high powered lasers, and other high heat generating processes and equipment
    • Displays temperature and pressure or flow rate simultaneously
    • User-adjustable temperature, pressure, and flow rate alarms
    • Simple operation and maintenance
    • Wide variety of options available
      To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing.
  • 50 Liter Short Path Distillation Package

    Summit offers ready to assemble short path distillation kits that come with a top of the line calibrated Genesis Mantles and complete glassware setup. Everything pictured is included. If you would like to modify or add components (swap out for a larger receiving flask or add a KF25 plug), just call us, we can work with you on mostly anything. Here is a list of everything included in this 50 liter kit, and a link for you to check them out in detail: Parts: Stands, crossbars and clamps sold separately. This kit takes 4-6 weeks as some parts are special order. Please contact Summit Research for pricing and availability at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified.
  • The Extraction Finder is a real-time molecular monitoring system for botanical extraction, which is essential for consistently maximizing the amount of extracted compounds within a given plant material. This robust model will serve hydrocarbon and ethanol extractions. Not rated for use with C02 extractions. The robust housing, which fully encloses the molecular sensor, can be easily installed in-line in the extraction design on sanitary flange end clamps. A 30′ sensor cable feeds this information to a high-quality touch-screen, which displays real-time levels of Cannabinoids, Chlorophyll and Lipids. The Extraction Finder’s digital readout can be used to help operators learn about and dial-in their process, such as optimizing flow rate, solvent amount, filter efficiency, and general quality assurance and control. In the long run, this system will be your best friend in dialing-in the most effective standard operating procedures (SOPs). Extraction Sensor
    • Housed and enclosed by the Extraction Sensor Housing
    • Connects and transmits to the digital display via 30′ sensor cable
    • Plug and play – instantaneously analyzes the mixture flowing through the processing machine
    Extraction Sensor Housing
    • Attaches directly onto sanitary flange connections (1.5″ or 2″) at any point in your extraction line
    • Houses the sensor, fully enclosing it from hazardous environments
    • C1D1/D2 certification
    Extraction Digital Display
    • Tablet-sized display mounts directly onto a lab pole
    • Connects and interprets the wavelength information from the sensor
    • Touch-screen interface displays real-time molecular information about the contents of the extraction fluid throughout the process
    • Includes long wiring, allowing it to be placed away from C1D1/D2 area
    Key Software Features:
    • Molecular Selection – Select from a growing list of key molecules, including Cannabinoids, Chlorophyll, and Lipids; see full list here
    • Intensity Values – Track as molecular intensity levels increase and decrease throughout the process
    • Data Logging – Record and export run data for traceability
    • Software Updates – Upgrade to software releases easily from the field (extraction finder software)
    Specifications
    • Maximum Pressure: 240Psi
    • Temperature: -70°C(min); 150°C(max)
    • Mounting Plate: Available as an add-on
    • Product Dimensions: 6.79in(L) x 5.39in(W)
    • Wavelength of Excitation: 365 nm
    • Optical Detection Range: 3001000 nm
    • Lower Detection Limit: <1mg/mL (at a volume of 1 cubic centimeter of oil)
    • Resolution: Spectral resolution is 15 nm max
    • Flow Rate Limit: No flow rate limit

    Lack of objectivity during the extraction process

    The purpose of botanical extraction processes, regardless of solvent used, is essentially to introduce a solvent to the biomass that will bind to, strip, and help obtain as much of the desirable compounds as possible. However, extraction operators have no solid metric to base their success on, aside from color in sight glasses or laboratory testing. While observing color can be done in-line, it is a subjective metric at best. While lab results are an objective metric, it is nearly impossible to correlate in practice and can take days or even weeks to obtain after a run. While both of these are helpful techniques that should be utilized during the process, they should not be solely relied upon since they lack real-time objectivity. Subjective monitoring that is based on perception or guesswork is imprecise, inconsistent, and difficult to scale. What is the effect of this lack of molecular monitoring during extraction? Batches that are sub-optimally extracted, resulting in either low yields or potency, and even wasted solvents and time. Examples of Applications The most popular applications of the Extraction Finder are hydrocarbon and ethanol extraction. The system can be installed in-line on extractors where there are 1.5” or 2” sanitary flange connections. Multiple units can be placed at multiple points of the extraction design. Hydrocarbon extraction: The unit can be installed in-line between the material column and collection column. Pre-filtration or CRC, the unit’s live data can help you determine what flow rate optimizes both solvated mass & time. Post-filtration or CRC, it can confirm that Chlorophyll is not making it past the filter. Ethanol extraction: The unit can be installed in-line at the recirculation area. It can be used to determine solvent saturation by seeing when the solvent has absorbed the majority of Cannabinoids. The unit is so sensitive that it can even be helpful for confirmation of removal of molecules during a cleaning run.

    Included in this package:

    • Extraction Finder Display
    • Extraction Sensor Housing with ultra-sensitive sensor
    • Power Supply, with 10′ Extension
    • Sensor Cable, 30′
    • Pole-Mounting Bracket
    • User Manual
    • Warranty Card
    More videos and conversations on our YouTube and Instagram https://youtu.be/dS7qr2g1Q5o
  • $4,299.99

    The HB Series Halo heads are inspired by our original fraction collector technology and have taken theses concepts to a new level. Halo technology allows for liquid temperature modulation at the top the head, dialing in your temps at a point in your short path distillation never before achieved. See the Halo in action: Instagram Demo instagram logo 34/45 key, 100mm clamp with O-ring and PTFE GL18s (4) included. 34/45 discharge port. Our 100mm heads fit exclusively to Summit flanged boiling flasks: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.     Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head HB2 Halo 100 To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing.
  • Liquid Temp Control Key 45/50 is a short path distillation head key that is used to generate a localized cold/hot surface. The temperature achieved reduces or enlarges the quantity of volatile material exhausted into the air. This premium Schott glass 45mm plug is 14.25 inch overall length and 10.5 inch from the bottom of the frosted taper with 4 large bands. High Temp GL14s included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Liquid Temp Control Key 45/50
  • Mechanical valve for the use with Apollo Vacuum Controller or SVG-3 This KF25 elbow valve works by throttling the pressure between the vacuum pump and the process to control the vacuum level or to isolate the vacuum pump | Enables vacuum pressure control using a solenoid valve for throttling pump suction
    • Control range: 10 millitorr to 6 Torr
    • Measurement range: 1 millitorr to 760 Torr
    • Range with accuracy: 10 millitorr to 6 Torr
    • Benefits of throttle control:  With the KF25 1″ orifice you get better and faster throughput | ideal for processing high volumes | Extends life of pump by enabling pump to run closer to it’s base pressure
    • Vacuum control—Regulate the vacuum level between the vacuum pump and the chamber or process. It creates a pressure drop between the two, thereby allowing the process to operate at a set pressure while the pumps’ pressure varies based on loading. Helps prolong the life of your vacuum pump!
    • Vacuum controller applications: Vacuum Ovens,  Vacuum Furnaces, Vacuum Bagging or Composites
    • Botanical processing: Rotary Evaporation, Short Path Distillation (1 Head Kit), Extractions
    • Use case example— To maintain specific pressure levels in a vacuum oven at about 2 Torr to avoid removing target terpenes and only removing water
  • The new SPD-8 Series Heads (FC55, 100mm, 150mm) bring a fraction collecting core combined with condenser coil. If you want absolute temperature control in a head, look no further. With these types of heads, if you dip the coil temp down it will act as a violent collection of molecules dragged to the coil like a magnet. That coil would inherently distribute those lower temps right on the surface of the fraction collector dish and that would display a whole new set of efficiency within the head. All Short Path Distillation 8 Heads have a 45/50 thermoport and a 34/45 discharge arm. Short Path Distillation 8 Head in use at the lab: Instagram Demo instagram logo The condenser in this 55/50 head absorbs as much heat as possible and removes BTU energy from the vapor prior to entering the condenser arm. This allows the vacuum jacketed head to operate like it’s supposed to. The coil in the head doesn’t disturb molecular flow dynamics as it’s duty is to absorb heat before the heat affects the sides of the walls of the fraction collector as well as allows those ambient vacuum void temps to be more stable. When you get blow by in a head it means it’s just working overtime because the arm sends back fluids to the heater chiller and it can’t maintain the BTU heat removal. So if you can maintain exact temps you can bounce unwanted fractions right out of the condenser arm without over shooting flow rates. This maintains a drier vacuum in the condenser arm. 45 Key Well, 45 Well Stopper and GL18s (4) included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation 8 Head FC55
  • The new SPD-8 Series Heads (FC55, 100mm, 150mm) bring a fraction collecting core combined with condenser coil. If you want absolute temperature control in a head, look no further. With these types of heads, if you dip the coil temp down it will act as a violent collection of molecules dragged to the coil like a magnet. That coil would inherently distribute those lower temps right on the surface of the fraction collector dish and that would display a whole new set of efficiency within the head. All Short Path Distillation 8 Heads have a 45/50 thermoport and a 34/45 discharge arm. Short Path Distillation 8 Head in use at the lab: Instagram Demo instagram logo The condenser in this 100mm head absorbs as much heat as possible and removes BTU energy from the vapor prior to entering the condenser arm. This allows the vacuum jacketed head to operate like it’s supposed to. The coil in the head doesn’t disturb molecular flow dynamics as it’s duty is to absorb heat before the heat affects the sides of the walls of the fraction collector as well as allows those ambient vacuum void temps to be more stable. When you get blow by in a head it means it’s just working overtime because the arm sends back fluids to the heater chiller and it can’t maintain the BTU heat removal. So if you can maintain exact temps you can bounce unwanted fractions right out of the condenser arm without over shooting flow rates. This maintains a drier vacuum in the condenser arm. Included with this head: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Boiling flask not included.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation 8 Head 100
  • The new SPD-8 Series Heads (FC55, 100mm, 150mm) bring a fraction collecting core combined with condenser coil. If you want absolute temperature control in a head, look no further. With these types of heads, if you dip the coil temp down it will act as a violent collection of molecules dragged to the coil like a magnet. That coil would inherently distribute those lower temps right on the surface of the fraction collector dish and that would display a whole new set of efficiency within the head. All Short Path Distillation 8 Heads have a 45/50 thermoport and a 34/45 discharge arm. Short Path Distillation 8 Head in use at the lab: Instagram Demo instagram logo The condenser in this 150mm head absorbs as much heat as possible and removes BTU energy from the vapor prior to entering the condenser arm. This allows the vacuum jacketed head to operate like it’s supposed to. The coil in the head doesn’t disturb molecular flow dynamics as it’s duty is to absorb heat before the heat affects the sides of the walls of the fraction collector as well as allows those ambient vacuum void temps to be more stable. When you get blow by in a head it means it’s just working overtime because the arm sends back fluids to the heater chiller and it can’t maintain the BTU heat removal. So if you can maintain exact temps you can bounce unwanted fractions right out of the condenser arm without over shooting flow rates. This maintains a drier vacuum in the condenser arm. Included with this head: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation 8 Head 150
  • The Short Path Distillation Head Bertha 150, since development in 2018, has become one of the leading standards in distillation head types in the industry. 2023 has brought the Bertha 100 to its final perfect form with 6 generations of evolution. This head comes equipped with 45/50 thermoport, 34/45 discharge port and a 100mm bore that secures to a boiling flask with o-ring and clamp. The Short Path Distillation Head Bertha 150 (previously SPD-4 MPD Big Bertha) is an extremely high vapor fractionation column head. The first section starts in the flask to retain as much heat in the column as possible. This entire column and entry into flask is isolated from the outside air and the flange fittings. The first chamber is a rough fractionation chamber with a lower rejection section that prevents any condensate from moving upwards. The center section is a secondary refinement section and will further refine the vapors. The upper third section is our patented fraction collector. The first dual stage fractionation column to ever be invented or used in distillation glassware, pilot or small scale. Can achieve 4-6 liters per hour (8 liters per hour with upgraded chilling and vacuum accessories) first pass and ready for crystallization. Vigs are not needed for this technology due to the industry first "no-vig" approach which utilizes a baffled section that extends down below the head base and into the boiling flask. Requirement to use these heads would be a sogevac + dual e2m30 -or- sogevac + e80 -or-  sogevac + e80 + diffusion array. This particular setup benefits from a custom diffusion array and an Apollo Vacuum Controller with the inert gas sweeping feature. Effectively increasing the stock speed and lowering the temperatures further. Included: Our MPD heads fit exclusively to Summit MPD boiling flasks: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head Bertha 150
  • $4,499.99

    The HB Series Halo heads are inspired by our original fraction collector technology and have taken theses concepts to a new level. Halo technology allows for liquid temperature modulation at the top the head, dialing in your temps at a point in your short path distillation never before achieved. See the Halo in action: Instagram Demo instagram logo 100mm clamp, O-ring and PTFE GL18s (4) included. Has 34/45 discharge port with built in key. Our 100mm heads fit exclusively to Summit flanged boiling flasks: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.     Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head HB1 Halo 100 To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing.
  • $4,849.99

    The HB Series Halo heads are inspired by our original fraction collector technology and have taken theses concepts to a new level. Halo technology allows for liquid temperature modulation at the top the head, dialing in your temps at a point in your short path distillation never before achieved. See the Halo in action: Instagram Demo instagram logo 150mm clamp, O-ring and PTFE GL18s (4) included. Has 34/45 discharge port with built in key. Our 150mm heads fit exclusively to Summit flanged boiling flasks: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.     Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head HB1 Halo 150 To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing.
  • $5,224.99

    The HB Series Halo heads are inspired by our original fraction collector technology and have taken theses concepts to a new level. Halo technology allows for liquid temperature modulation at the top the head, dialing in your temps at a point in your short path distillation never before achieved. See the Halo in action: Instagram Demo instagram logo 150mm clamp with O-ring and PTFE GL18s (4) included. 45/50 Key port and appropriate key & well stopper. 34/45 discharge port. Our 150mm heads fit exclusively to Summit flanged boiling flasks: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.     Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head HB2 Halo 150 To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing.
  • When the going gets tough, you can't ever be too safe! A triple coil intermediate trap with female 34/45 inlet and male outlet. This trapping mechanism is used as a laminar path connection recommended for larger short path distillation setups (22-50L) leading into dual cold traps. Heavy wall and joint thickness. Upgraded GL18 connections prevent barb breakage and mass body failure from stress of removing hoses. Extreme duty capacity and redesigned custom sized parallel flow coils that supply you with unmatched cooling. Collection flask port 45/50. Comes complete with: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Cold Trap 3 Shorty
  • KF40 Bellow

    From: $289.99
    The KF40 Bellow is a corrugated stainless steel pipe that connects to corresponding kf40 flanges. These malleable pipes allow for some error as apposed to hooking up a solid straight pipe. Available in 24 and 36 inch lengths. Don't forget other KF40 fittings and accessories: 100% stainless steel. 100% USA made. Bellow warning: Stretch and bend your bellow into position before installation. Engaging your pump(s) while not doing so could make the bellow jolt/jostle, putting stress on or damage glassware, voiding limited warranties. KF40 Bellow
  • Same as Filter Bottle Top 45 except thicker elongated port and an added GL18 to allow faster flow under vacuum. The elongated recessed port decreases fluid spray. Rodaviss, GL18 and GL14 included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Filter Top GL18 45
  • The KF16 to Male 24/40 PTFE Adapter is typically used to convert a glass system to a vacuum system or sensor. Adapter has 11mm bore. Secure your male connection with a keck clip. PTFE billet parts made right here in the USA. Be sure to have KF16x10 Centering Ring and KF16 clamp to make your KF16 connection.
  • Sale!

    Head Key 15 Band 24/40

    Original price was: $149.99.Current price is: $33.99.
    100% Schott glass 24/40 plug. 9 inch overall length (6 inches from bottom of frosted taper) with 15 bands. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Head Key 15 Band 24/40
  • $4,999.99

    The new SPD-8 Series Heads (FC55, 60mm, 100mm, 150mm) bring a fraction collecting core combined with condenser coil. If you want absolute temperature control in a head, look no further. With these types of heads, if you dip the coil temp down it will act as a violent collection of molecules dragged to the coil like a magnet. That coil would inherently distribute those lower temps right on the surface of the fraction collector dish and that would display a whole new set of efficiency within the head. All Short Path Distillation 8 Heads have a 45/50 thermoport and a 34/45 discharge arm. This 2 liter head comes with boiling flask! Can be upgraded to 5 liter flask, please call us. Short Path Distillation 8 Head in use at the lab: Instagram Demo instagram logo The condenser in this 60mm head absorbs as much heat as possible and removes BTU energy from the vapor prior to entering the condenser arm. This allows the vacuum jacketed head to operate like it’s supposed to. The coil in the head doesn’t disturb molecular flow dynamics as it’s duty is to absorb heat before the heat affects the sides of the walls of the fraction collector as well as allows those ambient vacuum void temps to be more stable. When you get blow by in a head it means it’s just working overtime because the arm sends back fluids to the heater chiller and it can’t maintain the BTU heat removal. So if you can maintain exact temps you can bounce unwanted fractions right out of the condenser arm without over shooting flow rates. This maintains a drier vacuum in the condenser arm. Included with this head: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation 8 Micro Head To purchase, please contact Summit Research at 8312262948 or by eMail. Limited run items ship 1-3 days after orders have been processed unless otherwise specified.
  • 1" Male JIC to KF25 adapter (Harvest Right Adapter) fits any KF25 flange. Summit's stainless adapters contain 100% USA made precision billet steel. Why choose an adapter with multiple parts and more chances to leak?
  • $8,800.00

    Polyscience 1.5hp Heavy Duty Chiller LO/BP has a LOW OUTPUT/BACK PRESSURE return system.  Exclusive to Summit, this 1.5hp offers more efficiency than the standard unit and comes in 100% stainless enclosure build out for a sexy look - 10l high temperature to 20l medium temperature rating for rotovaps. 220v
    • Small footprint conserves floor space
    • Displays temperature and pressure or flow rate simultaneously
    • User-adjustable temperature, pressure, and flow rate alarms
    • Simple operation and maintenance
    For detailed information visit polyscience.com To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing.
  • $6978.75

    6700 Polyscience series Heavy Duty 3/4 HP Chiller, Turbine Pump; 208-230V, 60Hz. Cooling Capacity at 20 deg C: 2300 W; Max Flow 3.5 gpm (13.2 l/min); Max Pressure 100 psi (6.9 bar)

    Features

    • Large, dual displays present temperature and pressure or flow rate simultaneously
    • Compact, portable design takes up less floor space
    • Cooling at ambient temperatures as high as 35°C
    • Positive displacement pump
    • Choice of compressor sizes
    • User-adjustable temperature, pressure, and flow rate alarms
    • External temperature tracking and communications capability (optional)
    • Cool Command™, WhisperCool® (3/4 and 1 HP models)
    To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing.
  • Cold Trap 3

    $1,999.99
    The Cold Trap 3 is a liquid cooled triple coiled beast! Eliminate the need for dry ice in your lab and hook up to a chiller. Female 34/45 inlet and outlet provides the bore your vacuum pumps desire. Extreme duty capacity and redesigned custom sized parallel flow coils that supply you with unmatched cooling. Daisy chain your chiller hosing top to bottom to include the Cold Trap 3 Flask. Collection flask port 45/50.
    • Heavy wall and joint thickness. Upgraded GL18 connections prevent barb breakage and mass body failure from stress of removing hoses.
    • 1 Liter liquid jacketed collection flask made with extra thick glass and extra thick joints using gl14s to the chiller.
    • Shorter overall height (21" please refer to schematic) allowing smaller footprint compared to other 1 liter collection cold traps. Allows closer placement to your work area with small stands compared to the typical wall mount or 42-44" iron foot stands.
    • Cold Trap 3 can be used to collect florals/terps, and using the lower flask you can reheat and steam the vapors up, re-condensing even 20ml of liquid up and back down to wash your florals/terps to the lower flask for capture and processing.
    Comes with: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Stands and clamps not included.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Cold Trap 3
  • The Swagelok DV-2 is a ball and needle 3/8 dual pump valve kit.  A high vacuum, 2 piece valve setup, rated for up to 8/9 scale. This item itself is a major tool in controlling vacuum or bleeding atmosphere into pump without risking any leak point. Swagelok is leading the industry in these types of valves. See for yourself: swagelok/valves
  • KF16x25 Reducer. Stainless steel adapter that reduces the size of your vacuum pipe diameter. Summit has other KF25 products in our Stainless Steel section.
  • KF16 to 1/4 Barb Adapter needs a KF16 Centering Ring and clamp. Stainless steel barb used for vacuum hose transitions. Summit has other KF16 items in our Vacuum Parts section. Summit recommends these items for this product:
  • Rodaviss SS Trap Adapter 45  fits directly on the bottom of your 45/50 cold trap. This billet stainless steel adapter secures seamlessly using a Rodaviss Kit (not included). SS 45F x 1/4 BSPP Threading. Billet stainless steel cold trap adapter.
  • The 29 SPD Discharge Adapter fits directly onto any glass 29/42 male or into a 29/42 KF25 adapter. Threads are 1/4 BSPP. Single adapter only. 100% Billet stainless steel and 100% USA made.
  • PLEASE CALL FOR AVAILABILITY. HB series heads are inspired by our patented fraction collector technology paired with a larger flanged bore. Short Path Distillation Head HB2 100 comes equipped with 34/45 key port, 34/45 discharge port and a 100mm bore that secures to a boiling flask with o-ring and clamp. The Short Path Distillation Head HB2 100, or previously SPD-4 MPD (modified path distillation), was created for one of our testers Breaking Dabs aka Heisenberg. With his unique skills he has helped us tune the HB series heads to evolve and provide solutions for our users. HB2 is designed to be ultra high speed with precision refinement. This head was bench marked by Heisenberg on a dual e2m30 array achieving 6 liters per hour without any effort at all. This head can be setup for very low temperatures, high clarity, and high speeds. Requirement to use these heads would be a sogevac + dual e2m30 -OR- sogevac + e80 -OR-  sogevac + e80 + diffusion array. This particular setup benefits from a custom diffusion array and an Apollo Vacuum Controller with the inert gas sweeping feature.  Effectively increasing the stock speed and lowering the temperatures further. The HB2 100mm head comes included with: Our flanged heads fit exclusively to Summit boiling flasks: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.   Base not included.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head HB2 100