usa made

  • Summit Research Tech offers a 4x Hochstrom filtration package that includes essential components for filtration :

    Hochstrom Filter ™

    The Hochstrom High Flow Filter is the fastest unit on the market. It’s unique design allows it to operate under half vacuum pressure for full flow. Our peers & customers have reported the high flow surface area to be equivalent to a 18-24″ table-top unit. These units have a huge basin, but small holes, really preventing it from being efficient for it’s size. A table top or small buchner filtration unit will have flow issues due to the solution warming up and redissolving past the filtration medium. You also get the fluid rushing around the filter media as well as a large surface area for liquids to warm up. We have achieved maximum efficiency in a much shorter time for filtration. This prevents items from warming up and redissolving and/or not securing. The Hochstrom filter is the last filter you will ever need to buy. Summit Research, only the best. 4x Hochstrom + 1x PIG Filtration Package.

    High Flow Paper for Hochstrom

    Stage 1 - 1000pcs of 20u chemical duty papers. Stage 2 - 1000pcs of 8u chemical duty papers. Stage 3 - 500pcs of sub 1u chemical duty 100% borosilicate papers(no chemical binder grade AE). All papers made in USA with no questionable composition, and no import junk. Straight up, best high flow papers you’ll ever use.

    20L Filter Bottle

    The 20L Filter Bottle is another original Summit Research product, going above and beyond to deliver a modified and custom filtration bottle. We chose to use genuine Schott media bottles. Had our shop mount the bottle on a lathe and remove the bung section while replacing it with a rodaviss female end. Summit have the highest quality modular caps custom made with male rodaviss joints. These flawless HEAVY DUTY glass filtration bottles are one of kind and found only at Summit. Accept no imitations, comes with rodaviss wet-seal parts and GL14 connections.

    PIG Filter

    This patented made in USA (pressurized inert gas) PIG Filtration System eats material. At an idle flow of 500 gallons per hour under winterization temperatures reported speeds exceeding 8 gallons per minute of filtration power. We are the Sole distributor of this product in our industry. Summit strives to bring new things to market and ensure the needs are met. https://youtu.be/_F65D3Skmj0   https://youtu.be/JWwV-icP4Dk   Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. 4x Hochstrom + 1x PIG Filtration Package
  • The Extraction Finder is a real-time molecular monitoring system for botanical extraction, which is essential for consistently maximizing the amount of extracted compounds within a given plant material. This robust model will serve hydrocarbon and ethanol extractions. Not rated for use with C02 extractions. The robust housing, which fully encloses the molecular sensor, can be easily installed in-line in the extraction design on sanitary flange end clamps. A 30′ sensor cable feeds this information to a high-quality touch-screen, which displays real-time levels of Cannabinoids, Chlorophyll and Lipids. The Extraction Finder’s digital readout can be used to help operators learn about and dial-in their process, such as optimizing flow rate, solvent amount, filter efficiency, and general quality assurance and control. In the long run, this system will be your best friend in dialing-in the most effective standard operating procedures (SOPs). Extraction Sensor
    • Housed and enclosed by the Extraction Sensor Housing
    • Connects and transmits to the digital display via 30′ sensor cable
    • Plug and play – instantaneously analyzes the mixture flowing through the processing machine
    Extraction Sensor Housing
    • Attaches directly onto sanitary flange connections (1.5″ or 2″) at any point in your extraction line
    • Houses the sensor, fully enclosing it from hazardous environments
    • C1D1/D2 certification
    Extraction Digital Display
    • Tablet-sized display mounts directly onto a lab pole
    • Connects and interprets the wavelength information from the sensor
    • Touch-screen interface displays real-time molecular information about the contents of the extraction fluid throughout the process
    • Includes long wiring, allowing it to be placed away from C1D1/D2 area
    Key Software Features:
    • Molecular Selection – Select from a growing list of key molecules, including Cannabinoids, Chlorophyll, and Lipids; see full list here
    • Intensity Values – Track as molecular intensity levels increase and decrease throughout the process
    • Data Logging – Record and export run data for traceability
    • Software Updates – Upgrade to software releases easily from the field (extraction finder software)
    Specifications
    • Maximum Pressure: 240Psi
    • Temperature: -70°C(min); 150°C(max)
    • Mounting Plate: Available as an add-on
    • Product Dimensions: 6.79in(L) x 5.39in(W)
    • Wavelength of Excitation: 365 nm
    • Optical Detection Range: 3001000 nm
    • Lower Detection Limit: <1mg/mL (at a volume of 1 cubic centimeter of oil)
    • Resolution: Spectral resolution is 15 nm max
    • Flow Rate Limit: No flow rate limit

    Lack of objectivity during the extraction process

    The purpose of botanical extraction processes, regardless of solvent used, is essentially to introduce a solvent to the biomass that will bind to, strip, and help obtain as much of the desirable compounds as possible. However, extraction operators have no solid metric to base their success on, aside from color in sight glasses or laboratory testing. While observing color can be done in-line, it is a subjective metric at best. While lab results are an objective metric, it is nearly impossible to correlate in practice and can take days or even weeks to obtain after a run. While both of these are helpful techniques that should be utilized during the process, they should not be solely relied upon since they lack real-time objectivity. Subjective monitoring that is based on perception or guesswork is imprecise, inconsistent, and difficult to scale. What is the effect of this lack of molecular monitoring during extraction? Batches that are sub-optimally extracted, resulting in either low yields or potency, and even wasted solvents and time. Examples of Applications The most popular applications of the Extraction Finder are hydrocarbon and ethanol extraction. The system can be installed in-line on extractors where there are 1.5” or 2” sanitary flange connections. Multiple units can be placed at multiple points of the extraction design. Hydrocarbon extraction: The unit can be installed in-line between the material column and collection column. Pre-filtration or CRC, the unit’s live data can help you determine what flow rate optimizes both solvated mass & time. Post-filtration or CRC, it can confirm that Chlorophyll is not making it past the filter. Ethanol extraction: The unit can be installed in-line at the recirculation area. It can be used to determine solvent saturation by seeing when the solvent has absorbed the majority of Cannabinoids. The unit is so sensitive that it can even be helpful for confirmation of removal of molecules during a cleaning run.

    Included in this package:

    • Extraction Finder Display
    • Extraction Sensor Housing with ultra-sensitive sensor
    • Power Supply, with 10′ Extension
    • Sensor Cable, 30′
    • Pole-Mounting Bracket
    • User Manual
    • Warranty Card
    More videos and conversations on our YouTube and Instagram https://youtu.be/dS7qr2g1Q5o
  • The new SPD-8 Series Heads (FC55, 100mm, 150mm) bring a fraction collecting core combined with condenser coil. If you want absolute temperature control in a head, look no further. With these types of heads, if you dip the coil temp down it will act as a violent collection of molecules dragged to the coil like a magnet. That coil would inherently distribute those lower temps right on the surface of the fraction collector dish and that would display a whole new set of efficiency within the head. All Short Path Distillation 8 Heads have a 45/50 thermoport and a 34/45 discharge arm. Short Path Distillation 8 Head in use at the lab: Instagram Demo instagram logo The condenser in this 150mm head absorbs as much heat as possible and removes BTU energy from the vapor prior to entering the condenser arm. This allows the vacuum jacketed head to operate like it’s supposed to. The coil in the head doesn’t disturb molecular flow dynamics as it’s duty is to absorb heat before the heat affects the sides of the walls of the fraction collector as well as allows those ambient vacuum void temps to be more stable. When you get blow by in a head it means it’s just working overtime because the arm sends back fluids to the heater chiller and it can’t maintain the BTU heat removal. So if you can maintain exact temps you can bounce unwanted fractions right out of the condenser arm without over shooting flow rates. This maintains a drier vacuum in the condenser arm. Included with this head: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation 8 Head 150
  • The Short Path Distillation Head Bertha 150, since development in 2018, has become one of the leading standards in distillation head types in the industry. 2023 has brought the Bertha 100 to its final perfect form with 6 generations of evolution. This head comes equipped with 45/50 thermoport, 34/45 discharge port and a 100mm bore that secures to a boiling flask with o-ring and clamp. The Short Path Distillation Head Bertha 150 (previously SPD-4 MPD Big Bertha) is an extremely high vapor fractionation column head. The first section starts in the flask to retain as much heat in the column as possible. This entire column and entry into flask is isolated from the outside air and the flange fittings. The first chamber is a rough fractionation chamber with a lower rejection section that prevents any condensate from moving upwards. The center section is a secondary refinement section and will further refine the vapors. The upper third section is our patented fraction collector. The first dual stage fractionation column to ever be invented or used in distillation glassware, pilot or small scale. Can achieve 4-6 liters per hour (8 liters per hour with upgraded chilling and vacuum accessories) first pass and ready for crystallization. Vigs are not needed for this technology due to the industry first "no-vig" approach which utilizes a baffled section that extends down below the head base and into the boiling flask. Requirement to use these heads would be a sogevac + dual e2m30 -or- sogevac + e80 -or-  sogevac + e80 + diffusion array. This particular setup benefits from a custom diffusion array and an Apollo Vacuum Controller with the inert gas sweeping feature. Effectively increasing the stock speed and lowering the temperatures further. Included: Our MPD heads fit exclusively to Summit MPD boiling flasks: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head Bertha 150
  • The new SPD-8 Series Heads (FC55, 100mm, 150mm) bring a fraction collecting core combined with condenser coil. If you want absolute temperature control in a head, look no further. With these types of heads, if you dip the coil temp down it will act as a violent collection of molecules dragged to the coil like a magnet. That coil would inherently distribute those lower temps right on the surface of the fraction collector dish and that would display a whole new set of efficiency within the head. All Short Path Distillation 8 Heads have a 45/50 thermoport and a 34/45 discharge arm. Short Path Distillation 8 Head in use at the lab: Instagram Demo instagram logo The condenser in this 100mm head absorbs as much heat as possible and removes BTU energy from the vapor prior to entering the condenser arm. This allows the vacuum jacketed head to operate like it’s supposed to. The coil in the head doesn’t disturb molecular flow dynamics as it’s duty is to absorb heat before the heat affects the sides of the walls of the fraction collector as well as allows those ambient vacuum void temps to be more stable. When you get blow by in a head it means it’s just working overtime because the arm sends back fluids to the heater chiller and it can’t maintain the BTU heat removal. So if you can maintain exact temps you can bounce unwanted fractions right out of the condenser arm without over shooting flow rates. This maintains a drier vacuum in the condenser arm. Included with this head: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Boiling flask not included.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation 8 Head 100
  • The new SPD-8 Series Heads (FC55, 100mm, 150mm) bring a fraction collecting core combined with condenser coil. If you want absolute temperature control in a head, look no further. With these types of heads, if you dip the coil temp down it will act as a violent collection of molecules dragged to the coil like a magnet. That coil would inherently distribute those lower temps right on the surface of the fraction collector dish and that would display a whole new set of efficiency within the head. All Short Path Distillation 8 Heads have a 45/50 thermoport and a 34/45 discharge arm. Short Path Distillation 8 Head in use at the lab: Instagram Demo instagram logo The condenser in this 55/50 head absorbs as much heat as possible and removes BTU energy from the vapor prior to entering the condenser arm. This allows the vacuum jacketed head to operate like it’s supposed to. The coil in the head doesn’t disturb molecular flow dynamics as it’s duty is to absorb heat before the heat affects the sides of the walls of the fraction collector as well as allows those ambient vacuum void temps to be more stable. When you get blow by in a head it means it’s just working overtime because the arm sends back fluids to the heater chiller and it can’t maintain the BTU heat removal. So if you can maintain exact temps you can bounce unwanted fractions right out of the condenser arm without over shooting flow rates. This maintains a drier vacuum in the condenser arm. 45 Key Well, 45 Well Stopper and GL18s (4) included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation 8 Head FC55
  • The Short Path Distillation Head Bertha 100, since development in 2018, has become one of the leading standards in distillation head types in the industry. 2023 has brought the Bertha 100 to its final perfect form with 6 generations of evolution. This head comes equipped with 45/50 thermoport, 34/45 discharge port and a 100mm bore that secures to a boiling flask with o-ring and clamp. The Short Path Distillation Head Bertha 100 (previously SPD-4 MPD Big Bertha) is an extremely high vapor fractionation column head. The first section starts in the flask to retain as much heat in the column as possible. This entire column and entry into flask is isolated from the outside air and the flange fittings. The first chamber is a rough fractionation chamber with a lower rejection section that prevents any condensate from moving upwards. The center section is a secondary refinement section and will further refine the vapors. The upper third section is our patented fraction collector. The first dual stage fractionation column to ever be invented or used in distillation glassware, pilot or small scale. Can achieve 2-4 liters per hour (6 liters per hour with upgraded chilling and vacuum accessories) first pass and ready for crystallization. Vigs are not needed for this technology due to the industry first "no-vig" approach which utilizes a baffled section that extends down below the head base and into the boiling flask. Requirement to use these heads would be a sogevac + dual e2m30 -or- sogevac + e80 -or-  sogevac + e80 + diffusion array. This particular setup benefits from a custom diffusion array and an Apollo Vacuum Controller with the inert gas sweeping feature. Effectively increasing the stock speed and lowering the temperatures further. Included: Our flanged heads fit exclusively to Summit MPD boiling flasks: Refer to our instructional (SPD-4 MPD Complete) for correct setup of this head. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head Bertha 100
  • HB series heads are inspired by our patented fraction collector technology paired with a larger flanged bore. Short Path Distillation Head HB1 150 comes equipped with 34/45 discharge port and a 150mm bore that secures to a boiling flask with o-ring and clamp. The Short Path Distillation Head HB1 150, or previously MPD (modified path distillation), was created for one of our testers Breaking Dabs aka Heisenberg. With his unique skills he has helped us tune the HB series heads to evolve and provide solutions for our users. HB1 is designed to be ultra selective to evacuate all previous fractions before the main body without letting the main body through. With some temp, main body can come out extremely fast and this head can be used as a first pass head. It is very effective in removing heads fractions while retaining main body components. Vigs are not needed for this technology due to the industry first "no-vig" approach which utilizes a baffled section that extends down below the head base and into the boiling flask. Please contact us for a completely tuned system with this hardware! Requirement to use these heads would be a sogevac + dual e2m30 -OR- sogevac + e80 -OR-  sogevac + e80 + diffusion array. This particular setup benefits from a custom diffusion array and an Apollo Vacuum Controller with the inert gas sweeping feature.  Effectively increasing the stock speed and lowering the temperatures further. The HB1 150mm head comes with: Our flanged heads fit exclusively to Summit boiling flasks: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head HB1 150 Please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified.
  • PLEASE CALL FOR AVAILABILITY. HB series heads are inspired by our patented fraction collector technology paired with a larger flanged bore. Short Path Distillation Head HB2 150 comes equipped with 45/50 key port, 34/45 discharge port and a 150mm bore that secures to a boiling flask with o-ring and clamp. The Short Path Distillation Head HB2 150, or previously MPD (modified path distillation), was created for one of our testers Breaking Dabs aka Heisenberg. With his unique skills he has helped us tune the HB series heads to evolve and provide solutions for our users. HB2 is designed to be ultra high speed with precision refinement. This head was bench marked by Heisenberg on a dual e2m30 array achieving 6 liters per hour without any effort at all. This head can be setup for very low temperatures, high clarity, and high speeds. Requirement to use these heads would be a sogevac + dual e2m30 -OR- sogevac + e80 -OR-  sogevac + e80 + diffusion array. This particular setup benefits from a custom diffusion array and an Apollo Vacuum Controller with the inert gas sweeping feature.  Effectively increasing the stock speed and lowering the temperatures further.   The HB2 150mm head comes included with: Our flanged heads fit exclusively to Summit boiling flasks: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head HB2 150 Please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified.
  • HB series heads are inspired by our patented fraction collector technology paired with a larger flanged bore. Short Path Distillation Head HB1 100 comes equipped with 34/45 discharge port and a 100mm bore that secures to a boiling flask with o-ring and clamp. The Short Path Distillation Head HB1 100, or previously SPD-4 MPD (modified path distillation), was created for one of our testers Breaking Dabs aka Heisenberg. With his unique skills he has helped us tune the HB series heads to evolve and provide solutions for our users. HB1 is designed to be ultra selective to evacuate all previous fractions before the main body without letting the main body through. With some temp, main body can come out extremely fast and this head can be used as a first pass head. It is very effective in removing heads fractions while retaining main body components. Vigs are not needed for this technology due to the industry first "no-vig" approach which utilizes a baffled section that extends down below the head base and into the boiling flask. Please contact us for a completely tuned system with this hardware! Requirement to use these heads would be a sogevac + dual e2m30 -OR- sogevac + e80 -OR-  sogevac + e80 + diffusion array. This particular setup benefits from a custom diffusion array and an Apollo Vacuum Controller with the inert gas sweeping feature.  Effectively increasing the stock speed and lowering the temperatures further. The HB1 100mm head comes with: Our flanged heads fit exclusively to Summit boiling flasks: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Boiling flask not included.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head HB1 100 Please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified.
  • Summit Research Fraction Finder figures out where components start and stop flowing to optimize separation. Making the SPD Process more precise and repeatable, Fraction Finding helps take the guess work out. Someone running a distillation can make better decisions if they knew exactly where they were in the distillation process. Scientists have developed expertise in this area to the point where they know what to expect. The Summit Research Fraction Finder does that for you and will be your best friend in short path distillation. Included with:
    • Standard sensor
    • Mounting hardware
    • Display screen
    • Light-blocking tape
    • Power Supply
    • Sensor Cable
    • User Manual and Quick Start Guide
    • 1-Year Warranty
    Through innovative live distillate monitoring, Fraction Finding can help increase potency on every distillation pass. Now, you can forget the old ways of relying on guesswork and eyesight, and instead, identify the contents of a flow through a glass tube in real time. Please contact Summit Research if you want to upgrade to the Ultra-Sensitive Fraction Finder. This new version can now be utilized on chromatography separations as well as your normal distillation processes. We now include FREE ATHENA SOFTWARE for download (Fraction Finder compatibility) More videos and conversations on our Instagram https://youtu.be/IPJVbMJlU_0

    Frequently Asked Questions

    Which fractions can the Fraction Finder detect? During short-path distillation, it can distinguish what is colloquially known as “Heads”, “Main Bodies”, and “Tails”. Click here for a list of molecules, such as Delta-9 and more. What units of measure does the Fraction Finder digital readout use?  The system uses Nanometers (nm) and Intensity (au). Can the Fraction Finder sensor fit on size 24 glass? If you have size 24 glass, order our 24/40 adapter, which can fit a size 29 sensor.  What heat can the Fraction Finder sensor handle? The Fraction Finder sensor can handle around 100 degrees Fahrenheit. If you plan to exceed these limits, order one of our Hot Tech Adapters. Does the Fraction Finder work the same as an HPLC? Both systems use spectroscopic analysis to identify chemicals. However, the type of spectroscopy that detection method and wavelength regime are different. The Fraction Finder operates uses fluorescence, whereas HPLCs utilize absorption.  
  • Summit Research offers a 2x Hochstrom Filtration Package that includes essential components for filtration : The Hochstrom High Flow Filter is the fastest unit on the market. It’s unique design allows it to operate under half vacuum pressure for full flow. Our peers & customers have reported the high flow surface area to be equivalent to a 18-24″ table-top unit. These units have a huge basin, but small holes, really preventing it from being efficient for it’s size. A table top or small buchner filtration unit will have flow issues due to the solution warming up and redissolving past the filtration medium. You also get the fluid rushing around the filter media as well as a large surface area for liquids to warm up. We have achieved maximum efficiency in a much shorter time for filtration. This prevents items from warming up and redissolving and/or not securing. The Hochstrom filter™ is the last filter you will ever need to buy. Summit Research, only the best. 2x Hochstrom Filtration Package. The 20L Filter Bottle is another original Summit Research product, going above and beyond to deliver a modified and custom filtration bottle. We chose to use genuine Schott media bottles. Had our shop mount the bottle on a lathe and remove the bung section while replacing it with a rodaviss female end. Summit have the highest quality modular caps custom made with male rodaviss joints. These flawless HEAVY DUTY glass filtration bottles are one of kind and found only at Summit. Accept no imitations, comes with rodaviss wet-seal parts and GL14 connections. Stage 1 - 1000pcs of 20u chemical duty papers. Stage 2 - 1000pcs of 8u chemical duty papers. Stage 3 - 500pcs of sub 1u chemical duty 100% borosilicate papers(no chemical binder grade AE). All papers made in USA with no questionable composition, and no import junk. Straight up, best high flow papers you’ll ever use.   https://youtu.be/_F65D3Skmj0   Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. 2x Hochstrom Filtration Package