- #29 Standard sensor
- Mounting hardware
- Display screen
- Light-blocking tape
- Power Supply
- Sensor Cable
- User Manual and Quick Start Guide
- 1-Year Warranty
-
Summit Research Fraction Finder figures out where components start and stop flowing to optimize separation. Making the short path distillation process more precise and repeatable, Fraction Finding takes the guess work out. Someone running a distillation can make better decisions if they knew exactly where they were in the distillation process. Scientists have developed expertise in this area to the point where they know what to expect. The Summit Research Fraction Finder does exactly that and will be your best friend in your laboratory. Included with:
-
The Flange Adapter 100mm is used to convert a flanged 100mm boiling flask to a 55mm (55/50) standard taper. You could utilize a different head or use a reflux condenser, the possibilities are endless. Glass unit only, clamp and O-ring not included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Flange Adapter 100mm
-
The Female to Male Reducer takes a 34/45 female port and reduces to a 24/40 male port. The possibilities with this adapter are endless. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Female to Male Reducer
-
$14,095.00
Specifications- Type of Product: Scroll Pump
- Manufacturer: Edwards
- Condition: New
- Part Number: A73001983
- Inlet: KF40
- Exhaust: KF25
- Motor: 1 Phase, 100-120/200-230V, 50/60Hz
- Pumping speed: 21 CFM
- Ultimate vacuum: 8 x 10-3 Torr
- Weight: 105 lbs
- closed loop temperature monitoring
- dry, clean vacuum free of lubricants
- simple, single-sided scroll design
- patented isolated bearing shield
- world-wide voltage compatibility
- low power consumption
- controllable gas ballast
- inverter driven motor
-
$16,710.00
Rebuilt Edwards E2M80 + Blower (mechanical booster) All air cooled dual stage Rotary Vane Pump, 208 V, 50 Hz/208-230 V, 60 Hz/460 V, 60 Hz, Three Phase with KF-40 inlet to blower. Edwards E2M series two stage oil sealed rotary vane vacuum pumps are renowned for their high ultimate vacuum, rapid pumping speeds, quiet operation and ability to handle water vapor. These direct drive rotary vane pumps are inherently compact and vibration free. Blowers add a dimension of vacuum that tops most dual pump options. Mechanical boosters feature the unique hydro-kinetic drive that provides pump down times cut by 50%, when compared with direct drive pumps, no bypass lines or pressure switches required, universal voltage motors, reduced capital and operating costs, air cooled motors – with water cooled options, and quiet, minimum vibration. Operating at relatively low pressures, the mechanical booster pump is not exposed to the same concentrations of corrosive process media as is the backing pump, which makes it highly reliable. Comes with Pump, Blower, MF100 filter and I 19 Standard fluid. To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing. -
$9,630.49
Rebuilt Edwards E2M40 + Blower (mechanical booster) All air cooled dual stage Rotary Vane Pump, 208 V, 50 Hz/208-230 V, 60 Hz/460 V, 60 Hz, Three Phase with KF-40 inlet to blower. Edwards E2M series two stage oil sealed rotary vane vacuum pumps are renowned for their high ultimate vacuum, rapid pumping speeds, quiet operation and ability to handle water vapor. These direct drive rotary vane pumps are inherently compact and vibration free. Blowers add a dimension of vacuum that tops most dual pump options. Mechanical boosters feature the unique hydro-kinetic drive that provides pump down times cut by 50%, when compared with direct drive pumps, no bypass lines or pressure switches required, universal voltage motors, reduced capital and operating costs, air cooled motors – with water cooled options, and quiet, minimum vibration. Operating at relatively low pressures, the mechanical booster pump is not exposed to the same concentrations of corrosive process media as is the backing pump, which makes it highly reliable. Comes with Pump, Blower, MF100 filter and I 19 Standard fluid. To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing. -
$7,275.00
Edwards E2M28, 1 Phase, 115-240V, 50/60Hz vacuum pump. Pump oil and EMF20 with accessories are included.- Type of product: Vane Pump
- Condition: New
- Inlet: KF25
- Exhaust: KF25
- Motor: 1 Phase, 115-240V, 50/60Hz
- Oil: Hydrocarbon
- Pumping speed: 19.5 CFM (60Hz)
- Ultimate pressure: 7.5 x 10-4 Torr (without gas ballast)
- Weight: 97 lbs
-
$6,831.25
Edwards E2M28, 1 Phase, 115-240V, 50/60Hz vacuum pump. Pump oil and EMF20 with accessories not included.- Type of product: Vane Pump
- Condition: New
- Inlet: KF25
- Exhaust: KF25
- Motor: 1 Phase, 115-240V, 50/60Hz
- Oil: Hydrocarbon
- Pumping speed: 19.5 CFM (60Hz)
- Ultimate pressure: 7.5 x 10-4 Torr (without gas ballast)
- Weight: 97 lbs
-
Dual Female 34 Adapter. Traditional 34/45 taper used to convert male connections together. The possibilities are endless. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Dual Female 34 Adapter
-
The Diamond Miner is a direct replacement to the mason jar or the steel and glass pressure chambers on the market. Completely jacketed so you can use a chiller such as the AD40-7L to control the temperature inside the chamber and set different ramp points to optimize diamond growth. Rated up to 30PSI so it can be used with many different solvents. This vessel is chemical resistant on all valves and seals. Included with (4) GL14 , (2) valve plungers, 100mm flange clamp and o-ring. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Pressure Vessel. Crystallization Diamond Miner
-
Cork Clamp with four prong cork jaw. One fixed side, one adjustable side.
- Maximum grip opening 3 5/8"
- Cylindrical arm length 6 1/4"
- Overall length 10 1/4"
-
Fits Size 29 Fraction Finder Sensor Details:
- Bundle that includes the Collection Jar Adapter and Collection Jar Mount
- For use with Wiped Film Evaporation systems, such as Root Sciences/VTA, to enable collected distillate to flow through the Size 29 Fraction Finder Sensor
- For use with Ball collection jar (not included)
-
This is a custom married part to the ultra short path distillation systems by Summit Research. A triple coil intermediate trap with 55/50 inlet and 34/45 outlet to cold trap. This trapping mechanism is used as a laminar path connection and can be ran hot or cold depending on your process. Extreme duty capacity and redesigned custom sized parallel flow coils that supply you with unmatched cooling. Collection flask port 45/50. Comes complete with: This cold trap fits exclusively with Summit's USPD setup:
- SPD-7 USPD (Head)
- RBF-22L-3N-USPD (Boiling Flask)
-
This is a custom married part to the ultra short path distillation systems by Summit Research. A dual coil intermediate trap with 45/50 inlet and 34/45 outlet to cold trap. This trapping mechanism is used as a laminar path connection and can be ran hot or cold depending on your process. Extreme duty capacity and redesigned custom sized parallel flow coils that supply you with unmatched cooling. Collection flask port 45/50. Comes complete with: This cold trap fits exclusively with Summit's Micro USPD setup:
- SPD-7.1 Micro USPD (Head)
- RBF-5L-3N-USPD (Boiling Flask)
-
When the going gets tough, you can't ever be too safe! A triple coil intermediate trap with female 34/45 inlet and male outlet. This trapping mechanism is used as a laminar path connection recommended for larger short path distillation setups (22-50L) leading into dual cold traps. Heavy wall and joint thickness. Upgraded GL18 connections prevent barb breakage and mass body failure from stress of removing hoses. Extreme duty capacity and redesigned custom sized parallel flow coils that supply you with unmatched cooling. Collection flask port 45/50. Comes complete with: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Cold Trap 3 Shorty
-
The Cold Trap 3 is a liquid cooled triple coiled beast! Eliminate the need for dry ice in your lab and hook up to a chiller. Female 34/45 inlet and outlet provides the bore your vacuum pumps desire. Extreme duty capacity and redesigned custom sized parallel flow coils that supply you with unmatched cooling. Daisy chain your chiller hosing top to bottom to include the Cold Trap 3 Flask. Collection flask port 45/50.
- Heavy wall and joint thickness. Upgraded GL18 connections prevent barb breakage and mass body failure from stress of removing hoses.
- 1 Liter liquid jacketed collection flask made with extra thick glass and extra thick joints using gl14s to the chiller.
- Shorter overall height (21" please refer to schematic) allowing smaller footprint compared to other 1 liter collection cold traps. Allows closer placement to your work area with small stands compared to the typical wall mount or 42-44" iron foot stands.
- Cold Trap 3 can be used to collect florals/terps, and using the lower flask you can reheat and steam the vapors up, re-condensing even 20ml of liquid up and back down to wash your florals/terps to the lower flask for capture and processing.
- Cold Trap 3 Flask
- Rodaviss
- Gl14 (2)
- GL18 (2)
-
The Cold Trap 2 Shorty (CT-2 Inv Cup Shorty) sets itself apart from others with its patented inverse cup technology. Vapors enter the cup, creating a turbulent vortex, then are forced to condense straight down ensuring proper dry vacuum protection to the pumps. Most traditional traps bypass vapors, only relying on cold surfaces, while this trap prevents nearly all vapors from bypassing. 34/45 female inlet and male outlet. 45/50 flask port. Comes included with: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Cold Trap 2 Shorty
-
Cold Trap 2 Hard Pipe with male 34/45 (from cold trap) and 34/45 female exit (to pumps). The straight pipe acts as a sight glass and is a great last line of defense to see if any moisture is reaching your pumps. Total length: 24.5 inches and 3.5 inches at top section. Hard pipe only, cold trap not included. Absolutely necessary XL Fork Clamp for the Hard Pipe of the Cold Trap 2. Not supporting your short path distillation setup properly will void any type of limited warranty. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. CT-2 Hard Pipe
-
The Cold Trap 2 (CT-2 Inv Cup) sets itself apart from others with its patented inverse cup technology. Vapors enter the cup, creating a turbulent vortex, then are forced to condense straight down ensuring proper dry vacuum protection to the pumps. Most traditional traps bypass vapors, only relying on cold surfaces, while this trap prevents nearly all vapors from bypassing. This trap comes with hard pipe to pumps. 34/45 female inlet and female outlet. 45/50 flask port. Included with: Absolutely necessary XL Fork Clamp for the Hard Pipe of the Cold Trap 2. Not supporting your short path distlllation setup properly will void any type of limited warranty. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Cold Trap 2
-
Sale!The Cold Trap 1 GL to GL (CT-1 Classic) is a borosilicate glass trap with GL18 port to dual GL18 to the pump. Traditional cold trap design to throw down wet vapor and keep your pumps dry. Comes complete with: Clamps and stands not included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Cold Trap 1 GL to GL
-
Sale!The Cold Trap 1 34 to GL (CT-1 semi-classic) is a borosilicate glass trap with 34/45 port to dual GL18 to the pump. Traditional cold trap design to throw down wet vapor and keep your pumps dry. Comes complete with: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Clamps and stands not included. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Cold Trap 1 34 to GL
-
Sale!Chromatography Column 6x48 (inches) with coarse/fine mixed frit and heavy wall thickness of 3mm. Comes with Rodaviss connection and 45/50 Chroma Cap (GL14 feed/vacuum port). The drain has a PTFE stopcock to GL18. All GLs are included. Chroma Cap has elongated recessed port with diffuser. This directs fluid spray against walls to gently fill the column and protect media from movement. All of our chromatography columns now have option to add an Ultra Sensitive Fraction Finder! Please use this column at your own risk! In addition to lab stands, it is recommended that you secure the lab stands to a wall or sturdy foundation while also using sandbags. This column will surpass 100+ lbs of weight holding full fluid. Please make sure you are offsetting the weight of your fluids. Summit requires this chromatography column to be supported by 3 chain clamps and a top mounted cork clamp. Summit recommends applying a thin rubber strip (the length of the chains contact) under the chain clamps (not included) to maximize grip. This column may slip though clamps if not properly bottom supported. Recommended (yet again), to have a lab tripod base (use rubber stripping here as well) or circle clamp about 5" diameter (not included)(last picture). The 6x48 Chromatography Column has no warranty. Stands , clamps and sandbags not included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment you deserve for all your chromatography and CRC proccess's. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Chromatography Column 6x48
-
Sale!Chromatography Column 5x48 (inches) with coarse/fine mixed frit. Heavy wall thickness of 3mm. Comes with Rodaviss connection and 45/50 Chroma Cap (GL14 feed/vacuum port). The drain has a PTFE stopcock to GL18. All GLs are included. Chroma Cap has elongated recessed port with diffuser. This directs fluid spray against walls to gently fill the column and protect media from movement. All of our chromatography columns now have option to add an Ultra Sensitive Fraction Finder! In addition to lab stands, it is recommended that you secure the lab stands to a wall or sturdy foundation while also using sandbags. This column will surpass 80+ lbs of weight holding full fluid. Please make sure you are offsetting the weight of your fluids. Summit requires this chromatography column to be supported by 3 chain clamps and a top mounted cork clamp. Summit recommends applying a thin rubber strip (the length of the chains contact) under the chain clamps (not included) to maximize grip. This column may slip though clamps if not properly bottom supported. Recommended (yet again), to have a lab tripod base (use rubber stripping here as well) or circle clamp base about 4″ diameter (not included)(last picture). Stands , clamps and sandbag are not included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment you deserve for all your chromatography and CRC proccess's. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Chromatography Column 5x48
-
Chromatography Column 4x48 (inches) with coarse/fine mixed frit. Heavy wall thickness of 3mm. Comes with Rodaviss connection and 45/50 Chroma Cap (GL14 feed/vacuum port). The drain has a PTFE stopcock to GL18. All GLs are included. Chroma Cap has elongated recessed port with diffuser. This directs fluid spray against walls to gently fill the column and protect media from movement. All of our chromatography columns now have option to add an Ultra Sensitive Fraction Finder! To comply with warranty, Summit requires this chromatography column to be supported by 2 chain clamps and a top mounted cork clamp. Summit recommends applying a thin rubber strip (the length of the chains contact) under the chain clamps (not shown) to maximize grip. For this larger size column, Summit requires applying weight to the stand base such as a sand bag or something equivalent of 50 lbs+ (something to offset the weight of your fluids) As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment you deserve for all your chromatography and CRC proccess's. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Chromatography Column 4x48
-
Chromatography Column 4x36 (inches) with coarse/fine mixed frit. Heavy wall thickness of 3mm. Comes with Rodaviss connection and 45/50 Chroma Cap (GL14 feed/vacuum port). The drain has a PTFE stopcock to GL18. All GLs are included. Chroma Cap has elongated recessed port with diffuser. This directs fluid spray against walls to gently fill the column and protect media from movement. All of our chromatography columns now have option to add an Ultra Sensitive Fraction Finder! To comply with warranty, Summit requires this chromatography column to be supported by 2 chain clamps and a top mounted cork clamp. Summit recommends applying a thin rubber strip (the length of the chains contact) under the chain clamps (not shown) to maximize grip. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment you deserve for all your chromatography and CRC proccess's. Lab stands and clamps not included. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Chromatography Column 4x36
-
Chroma Column FF 6x48 with coarse/fine mixed frit and heavy wall thickness of 3mm. Special design allows for #29 Fraction Finder that permits you to check your fraction and watch your progression. Attach a FF between the frit and the stopcock area. Comes with rodaviss , GL18 and #45 Chroma Cap. Fraction Finder not included. All of our chromatography columns now have option to add an Ultra Sensitive Fraction Finder! Please use this column at your own risk! In addition to lab stands, it is recommended that you secure the lab stands to a wall or sturdy foundation while also using sandbags. This column will surpass 100+ lbs of weight holding full fluid. Please make sure you are offsetting the weight of your fluids. Summit requires this chromatography column to be supported by 3 chain clamps and a top mounted cork clamp. Summit recommends applying a thin rubber strip (the length of the chains contact) under the chain clamps (not included) to maximize grip. This column may slip though clamps if not properly bottom supported. Recommended (yet again), to have a lab tripod base (use rubber stripping here as well) or a circular clamp about 5" diameter (not included)(last picture). The Chroma Column FF 6x48 has no warranty. https://www.instagram.com/p/B5Lv5CzBAS-/ As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment you deserve for all your chromatography and CRC proccess's. Stands, clamps, sandbag and Fraction Finder are not included. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Chroma Column FF 6x48
-
The Boiling Flask 12L-3N-45 is made from high quality Schott glass, this is the original Rundkolben (triple offset joints) 3 neck round bottom flask. The most popular and strongest distillation flask of its kind. The dimensions and geometry of the joints are original concepts brought to market by Summit Research. Joints are standard taper 24/40 (2) and 45/50 main. 12 Liter flask. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Boiling Flask 12L-3N-45
-
$17,500.00
A BINDER safety vacuum drying oven ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber of the VDL safety vacuum drying oven is designed according to ATEX guidelines 2014/34/EU Ex II 3/-G Ex h IIB T1-T3 Gc X.Benefits
Important characteristics
Performance Data Temperature Heating-up time to 100 °C [min] 95 Temperature fluctuation [± K] 0.1 Temperature range 15 °C above ambient temperature to [°C] 200 Temperature variation at 100 °C [± K] 3.5 Vacuum Data Leak rate [bar/h] 0.01 Permitted end vacuum [mbar] 0.01 Electrical data Nominal power [kW] 1.9 Phase (Nominal voltage) 1~ Power frequency [Hz] 50/60 Rated Voltage [V] 230 Unit fuse [A] 10 Connections Compressed air connection for pressure-encapsulation 8 mm Inert gas connection with flow limiter (RP") 3/8 Measuring access port with small flange [DN mm] 16 Vacuum connection with small flange [DN mm] 16 Housing dimensions not incl. fittings and connections Depth net [in] 26.4 Height net [in] 35.46 Width net [in] 29.16 Internal Dimensions Depth [in] 18.12 Height [in] 19.94 Width [in] 19.94 Measures Interior volume [cu.ft.] 4.1 Load per rack [lbs] 44 Net weight of the unit (empty) [lbs] 337 Permitted load [lbs] 143 Viewing window height [in] 16.27 Viewing window width [in] 17.97 Wall clearance back [in] 3.94 Wall clearance sidewise [in] 5.32 Fixtures Number of shelves (std./max.) 2/6 Further information (Data Sheets, Operating Manuals and Technical Drawings) can be downloaded from BINDER. A Basic vacuum oven diagram can be seen/downloaded here:-
All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing.
-
-
$13,500.00
A BINDER safety vacuum drying oven ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber of the VDL safety vacuum drying oven is designed according to ATEX guidelines 2014/34/EU Ex II 3/-G Ex h IIB T1-T3 Gc X.Benefits
Important characteristics
Performance Data Temperature Heating-up time to 100 °C [min] 80 Temperature fluctuation [± K] 0.1 Temperature range 15 °C above ambient temperature to [°C] 200 Temperature variation at 100 °C [± K] 2 Vacuum Data Leak rate [bar/h] 0.01 Permitted end vacuum [mbar] 0.01 Electrical data Nominal power [kW] 1.2 Phase (Nominal voltage) 1~ Power frequency [Hz] 50/60 Rated Voltage [V] 230 Unit fuse [A] 10 Connections Compressed air connection for pressure-encapsulation 8 mm Inert gas connection with flow limiter (RP") 3/8 Measuring access port with small flange [DN mm] 16 Vacuum connection with small flange [DN mm] 16 Housing dimensions not incl. fittings and connections Depth net [in] 21.67 Height net [in] 30.53 Width net [in] 25.02 Internal Dimensions Depth [in] 13.4 Height [in] 15.76 Width [in] 15.76 Measures Interior volume [cu.ft.] 1.9 Load per rack [lbs] 44 Net weight of the unit (empty) [lbs] 209 Permitted load [lbs] 99 Viewing window height [in] 12.1 Viewing window width [in] 13.79 Wall clearance back [in] 3.94 Wall clearance sidewise [in] 5.32 Fixtures Number of shelves (std./max.) 2/5 Further information (Data Sheets, Operating Manuals and Technical Drawings) can be downloaded from BINDER. A Basic vacuum oven diagram can be seen/downloaded here:-
All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing.
-