spd

  • Sale!

    Short Path Distillation Head FC34

    Original price was: $1,050.00.Current price is: $749.99.
    The Short Path Distillation Head FC34 (spd-2 fc34) has been upgraded with our new fraction collector technology. This head runs specifically for smaller setups (2L & 5L). Equipped with #34 bore, #29 discharge arm and #24 key port. All tapers are traditional. When Summit Research initially released the first fraction collector technology we knew it would be a hit. We have innovated the newest distillation technology with the industry leading high-efficiency heads. We have retrofitted all Summit Research heads to incorporate our patented distillation technology. The fraction collector head offers extremely high-efficiency operational parameters unparalleled to anything available on the market. Summit delivers solutions and results to our customers coming from extensive research and design in the field of high speed, high potency, low temperature, consistent distillations day after day. The differences between the FC series heads are the heights. Lower height heads will have less selectivity with faster speeds and lower temps, taller heads will have slower speeds with slightly higher temps with more selectivity. Partnered with our patented laminar path technology and the inverted cup cold trap/hardpipe kits, our customers experience smooth, fast and consistent clarity time after time. This FC34 head holds a medium height and 2 levels of vigreux for medium rejection. A traditional all around head that will stand the test of time. Refer to our instructional (SPD-2 FC34 Complete) for correct setup of this head. GL14s and key included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head FC34
  • The Short Path Distillation Head Bertha 150, since development in 2018, has become one of the leading standards in distillation head types in the industry. 2023 has brought the Bertha 100 to its final perfect form with 6 generations of evolution. This head comes equipped with 45/50 thermoport, 34/45 discharge port and a 100mm bore that secures to a boiling flask with o-ring and clamp. The Short Path Distillation Head Bertha 150 (previously SPD-4 MPD Big Bertha) is an extremely high vapor fractionation column head. The first section starts in the flask to retain as much heat in the column as possible. This entire column and entry into flask is isolated from the outside air and the flange fittings. The first chamber is a rough fractionation chamber with a lower rejection section that prevents any condensate from moving upwards. The center section is a secondary refinement section and will further refine the vapors. The upper third section is our patented fraction collector. The first dual stage fractionation column to ever be invented or used in distillation glassware, pilot or small scale. Can achieve 4-6 liters per hour (8 liters per hour with upgraded chilling and vacuum accessories) first pass and ready for crystallization. Vigs are not needed for this technology due to the industry first "no-vig" approach which utilizes a baffled section that extends down below the head base and into the boiling flask. Requirement to use these heads would be a sogevac + dual e2m30 -or- sogevac + e80 -or-  sogevac + e80 + diffusion array. This particular setup benefits from a custom diffusion array and an Apollo Vacuum Controller with the inert gas sweeping feature. Effectively increasing the stock speed and lowering the temperatures further. Included: Our MPD heads fit exclusively to Summit MPD boiling flasks: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head Bertha 150
  • The Short Path Distillation Head Bertha 100, since development in 2018, has become one of the leading standards in distillation head types in the industry. 2023 has brought the Bertha 100 to its final perfect form with 6 generations of evolution. This head comes equipped with 45/50 thermoport, 34/45 discharge port and a 100mm bore that secures to a boiling flask with o-ring and clamp. The Short Path Distillation Head Bertha 100 (previously SPD-4 MPD Big Bertha) is an extremely high vapor fractionation column head. The first section starts in the flask to retain as much heat in the column as possible. This entire column and entry into flask is isolated from the outside air and the flange fittings. The first chamber is a rough fractionation chamber with a lower rejection section that prevents any condensate from moving upwards. The center section is a secondary refinement section and will further refine the vapors. The upper third section is our patented fraction collector. The first dual stage fractionation column to ever be invented or used in distillation glassware, pilot or small scale. Can achieve 2-4 liters per hour (6 liters per hour with upgraded chilling and vacuum accessories) first pass and ready for crystallization. Vigs are not needed for this technology due to the industry first "no-vig" approach which utilizes a baffled section that extends down below the head base and into the boiling flask. Requirement to use these heads would be a sogevac + dual e2m30 -or- sogevac + e80 -or-  sogevac + e80 + diffusion array. This particular setup benefits from a custom diffusion array and an Apollo Vacuum Controller with the inert gas sweeping feature. Effectively increasing the stock speed and lowering the temperatures further. Included: Our flanged heads fit exclusively to Summit MPD boiling flasks: Refer to our instructional (SPD-4 MPD Complete) for correct setup of this head. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation Head Bertha 100
  • $4,999.99

    The new SPD-8 Series Heads (FC55, 60mm, 100mm, 150mm) bring a fraction collecting core combined with condenser coil. If you want absolute temperature control in a head, look no further. With these types of heads, if you dip the coil temp down it will act as a violent collection of molecules dragged to the coil like a magnet. That coil would inherently distribute those lower temps right on the surface of the fraction collector dish and that would display a whole new set of efficiency within the head. All Short Path Distillation 8 Heads have a 45/50 thermoport and a 34/45 discharge arm. This 2 liter head comes with boiling flask! Can be upgraded to 5 liter flask, please call us. Short Path Distillation 8 Head in use at the lab: Instagram Demo instagram logo The condenser in this 60mm head absorbs as much heat as possible and removes BTU energy from the vapor prior to entering the condenser arm. This allows the vacuum jacketed head to operate like it’s supposed to. The coil in the head doesn’t disturb molecular flow dynamics as it’s duty is to absorb heat before the heat affects the sides of the walls of the fraction collector as well as allows those ambient vacuum void temps to be more stable. When you get blow by in a head it means it’s just working overtime because the arm sends back fluids to the heater chiller and it can’t maintain the BTU heat removal. So if you can maintain exact temps you can bounce unwanted fractions right out of the condenser arm without over shooting flow rates. This maintains a drier vacuum in the condenser arm. Included with this head: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation 8 Micro Head To purchase, please contact Summit Research at 8312262948 or by eMail. Limited run items ship 1-3 days after orders have been processed unless otherwise specified.
  • The new SPD-8 Series Heads (FC55, 100mm, 150mm) bring a fraction collecting core combined with condenser coil. If you want absolute temperature control in a head, look no further. With these types of heads, if you dip the coil temp down it will act as a violent collection of molecules dragged to the coil like a magnet. That coil would inherently distribute those lower temps right on the surface of the fraction collector dish and that would display a whole new set of efficiency within the head. All Short Path Distillation 8 Heads have a 45/50 thermoport and a 34/45 discharge arm. Short Path Distillation 8 Head in use at the lab: Instagram Demo instagram logo The condenser in this 55/50 head absorbs as much heat as possible and removes BTU energy from the vapor prior to entering the condenser arm. This allows the vacuum jacketed head to operate like it’s supposed to. The coil in the head doesn’t disturb molecular flow dynamics as it’s duty is to absorb heat before the heat affects the sides of the walls of the fraction collector as well as allows those ambient vacuum void temps to be more stable. When you get blow by in a head it means it’s just working overtime because the arm sends back fluids to the heater chiller and it can’t maintain the BTU heat removal. So if you can maintain exact temps you can bounce unwanted fractions right out of the condenser arm without over shooting flow rates. This maintains a drier vacuum in the condenser arm. 45 Key Well, 45 Well Stopper and GL18s (4) included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation 8 Head FC55
  • The new SPD-8 Series Heads (FC55, 100mm, 150mm) bring a fraction collecting core combined with condenser coil. If you want absolute temperature control in a head, look no further. With these types of heads, if you dip the coil temp down it will act as a violent collection of molecules dragged to the coil like a magnet. That coil would inherently distribute those lower temps right on the surface of the fraction collector dish and that would display a whole new set of efficiency within the head. All Short Path Distillation 8 Heads have a 45/50 thermoport and a 34/45 discharge arm. Short Path Distillation 8 Head in use at the lab: Instagram Demo instagram logo The condenser in this 150mm head absorbs as much heat as possible and removes BTU energy from the vapor prior to entering the condenser arm. This allows the vacuum jacketed head to operate like it’s supposed to. The coil in the head doesn’t disturb molecular flow dynamics as it’s duty is to absorb heat before the heat affects the sides of the walls of the fraction collector as well as allows those ambient vacuum void temps to be more stable. When you get blow by in a head it means it’s just working overtime because the arm sends back fluids to the heater chiller and it can’t maintain the BTU heat removal. So if you can maintain exact temps you can bounce unwanted fractions right out of the condenser arm without over shooting flow rates. This maintains a drier vacuum in the condenser arm. Included with this head: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation 8 Head 150
  • The new SPD-8 Series Heads (FC55, 100mm, 150mm) bring a fraction collecting core combined with condenser coil. If you want absolute temperature control in a head, look no further. With these types of heads, if you dip the coil temp down it will act as a violent collection of molecules dragged to the coil like a magnet. That coil would inherently distribute those lower temps right on the surface of the fraction collector dish and that would display a whole new set of efficiency within the head. All Short Path Distillation 8 Heads have a 45/50 thermoport and a 34/45 discharge arm. Short Path Distillation 8 Head in use at the lab: Instagram Demo instagram logo The condenser in this 100mm head absorbs as much heat as possible and removes BTU energy from the vapor prior to entering the condenser arm. This allows the vacuum jacketed head to operate like it’s supposed to. The coil in the head doesn’t disturb molecular flow dynamics as it’s duty is to absorb heat before the heat affects the sides of the walls of the fraction collector as well as allows those ambient vacuum void temps to be more stable. When you get blow by in a head it means it’s just working overtime because the arm sends back fluids to the heater chiller and it can’t maintain the BTU heat removal. So if you can maintain exact temps you can bounce unwanted fractions right out of the condenser arm without over shooting flow rates. This maintains a drier vacuum in the condenser arm. Included with this head: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Boiling flask not included.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Short Path Distillation 8 Head 100
  • The Sensor Ultra Sensitive features the brand new, ultra-sensitive sensor. This package is unique in that - not only does it serve distillation and extraction processes - but also serves Chromatography, Conversion Reaction, and other processes that require more extreme detection. For certain processes, highly sensitive process monitoring is essential. Generally speaking, the more solvent involved in the process means the more sensitive the sensor needs to be. With that in mind, the ULTRA was created. If you are an existing customer, you have the option to upgrade to a standalone ULTRA Sensor for $1,350. Please call us for more details. Use this sensor on any chromatography column with the GL18 to #34 adapter. The Fraction Finder Sensor 34/45 consists of an optical light pulse and detector, acting as “the eyes” of the system. It wraps around a distillation/chromatography setup tube and connects to the Fraction Finder display to track important data on the process.
    • Fraction Finder optical sensor with ultra-sensitive detector
    • Magnetic locking mechanism
    • Anodized aluminum apertures
    • 90° strap rotation
    • Currently only available in size 34mm
    • Validated by Arometrix for use on distillation systems
    • Currently being tested on reverse-phase chromatography processes
    • Display and sight glass not included

    Information common with all Fraction Finder sensors

    These sensors are black for a reason:
    • Black absorbs all light while blocking out ambient light.
    • This leads to better signaling and the most valid data possible transmitting to the Fraction Finder display.
    • For example, a white sensor wouldn’t work because it would reflect the light into your glassware and into the sensor, harming the reading.
    Chemical Resistant
    • This reduces any degradation from solvents, crude oils, extracts, etc..
    • This protects the sensor and ensures that it lives to see an endless amount of runs.
    Thermo Resistant / Safety
    • The black coating we use on each sensor is a high temperature, thermal resistant coating, it can withstand temperatures well above anything you’d see in a distillation lab.
    • It’s nearly impossible to set one of our sensors on fire, the coating is almost completely fireproof!
    • This protects the user, the equipment, and (in worst case scenarios) the entire lab.
    Sensor only, monitor and accessories not included.
  • Sensor #34

    $2,094.99
    The Fraction Finder Sensor #34 consists of an optical light pulse and detector, acting as “the eyes” of the system. It wraps around a distillation set up condenser tube and connects to the Fraction Finder display to track important data on the distillation. These sensors are black for a reason:
    • Black absorbs all light while blocking out ambient light.
    • This leads to better signaling and the most valid data possible transmitting to the Fraction Finder display.
    • For example, a white sensor wouldn’t work because it would reflect the light into your glassware and into the sensor, harming the reading.
    Chemical Resistant
    • This reduces any degradation from solvents, crude oils, extracts, etc..
    • This protects the sensor and ensures that it lives to see an endless amount of runs.
    Thermo Resistant / Safety
    • The black coating we use on each sensor is a high temperature, thermal resistant coating, it can withstand temperatures well above anything you’d see in a distillation lab.
    • It’s nearly impossible to set one of our sensors on fire, the coating is almost completely fireproof!
    • This protects the user, the equipment, and (in worst case scenarios) the entire lab.
    Sensor only, monitor and accessories not included.
  • Sensor #29

    $1,919.99
    The Fraction Finder Sensor #29 consists of an optical light pulse and detector, acting as “the eyes” of the system. It wraps around a distillation set up condenser tube and connects to the Fraction Finder display to track important data on the distillation. These sensors are black for a reason:
    • Black absorbs all light while blocking out ambient light.
    • This leads to better signaling and the most valid data possible transmitting to the Fraction Finder display.
    • For example, a white sensor wouldn’t work because it would reflect the light into your glassware and into the sensor, harming the reading.
    Chemical Resistant
    • This reduces any degradation from solvents, crude oils, extracts, etc..
    • This protects the sensor and ensures that it lives to see an endless amount of runs.
    Thermo Resistant / Safety
    • The black coating we use on each sensor is a high temperature, thermal resistant coating, it can withstand temperatures well above anything you’d see in a distillation lab.
    • It’s nearly impossible to set one of our sensors on fire, the coating is almost completely fireproof!
    • This protects the user, the equipment, and (in worst case scenarios) the entire lab.
    Sensor only, monitor and accessories not included.
  • Rodaviss SS Trap Adapter 45  fits directly on the bottom of your 45/50 cold trap. This billet stainless steel adapter secures seamlessly using a Rodaviss Kit (not included). SS 45F x 1/4 BSPP Threading. Billet stainless steel cold trap adapter.
  • Receiving Flask 29/42 500ml round bottom flask designed with a 29mm standard taper joint. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Receiving Flask 29/42 500ml