  • Sale!
    Chromatography Column 5x48 (inches) with coarse/fine mixed frit. Heavy wall thickness of 3mm. Comes with Rodaviss connection and 45/50 Chroma Cap (GL14 feed/vacuum port). The drain has a PTFE stopcock to GL18. All GLs are included. Chroma Cap has elongated recessed port with diffuser. This directs fluid spray against walls to gently fill the column and protect media from movement. All of our chromatography columns now have option to add an Ultra Sensitive Fraction Finder! In addition to lab stands, it is recommended that you secure the lab stands to a wall or sturdy foundation while also using sandbags. This column will surpass 80+ lbs of weight holding full fluid. Please make sure you are offsetting the weight of your fluids. Summit requires this chromatography column to be supported by 3 chain clamps and a top mounted cork clamp. Summit recommends applying a thin rubber strip (the length of the chains contact) under the chain clamps (not included) to maximize grip. This column may slip though clamps if not properly bottom supported. Recommended (yet again), to have a lab tripod base (use rubber stripping here as well) or circle clamp base about 4″ diameter (not included)(last picture). Stands , clamps and sandbag are not included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment you deserve for all your chromatography and CRC proccess's.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Chromatography Column 5x48
  • Sale!
    Stage 1 - 1000pcs of 20u chemical duty paper. Stage 2 - 1000pcs of 8u chemical duty paper. Stage 3 - 500pcs of sub 1u chemical duty 100% borosilicate paper (no chemical binder grade AE). These circular papers have a 142mm diameter (5.6 inch). All papers made in USA with no questionable composition, and no import junk. Straight up, best high flow papers you’ll ever use.
    • Comes with steps 1, 2 & 3 Hochstrom Filter™ high flow paper
  • The Filter Bottle 10 Liter is genuine thick Schott glass media. We spared no cost to have our shop mount the bottle on a lathe and remove the bung section, replacing it with a Rodaviss female end. These flawless HEAVY DUTY glass filtration bottles are one of kind and come with Rodaviss wet-seal parts, Filter Bottle Top and High Temp PTFE GL14 connections. THIS ITEM DOES NOT HAVE A WARRANTY AND SHOULD BE TREATED WITH CARE ON A RUBBER MAT, WITHOUT OVER TIGHTENING THE TOP. RETURNS FOR DAMAGED BOTTLES WILL BE REFUSED UNCONDITIONALLY. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve for your filtration process's.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. 10L Filter Bottle
  • Pressurized fluid and solution stainless steel handling keg. 2 inch diameter tri-clamp. Full chemical duty. Choice of 5 gallon or 15 gallon. Whether running hot or cold, pressurized or not, these durable kegs get the job done. Made in USA. Comes with clamp, o-ring, two port lid and 3/8 nipples. Keg measures 26inches x 15.5inches.
  • This is an additional package to the original Hochstrom high flow filtration unit. It comes with one plate, one ring and one tall tube cut for dual plate arrangement (The cut is double sized to allow two plates). Adding another plate will refine your product even more and save you that extra run, thus cutting your time in half. The original Hochstrom Filter ™ comes with single plate arrangement. Hochstrom threaded base, nipple and viton O-rings not included.   The Hochstrom High Flow Filter is the fastest unit on the market. It’s unique design allows it to operate under half vacuum pressure for full flow. Our peers & customers have reported the high flow surface area to be equivalent to a 18-24″ table-top unit. These units have a huge basin, but small holes, really preventing it from being efficient for it’s size. A table top or small buchner filtration unit will have flow issues due to the solution warming up & redissolving past the filtration medium. You also get the fluid rushing around the filter media as well as a large surface area for liquids to warm up. We have achieved maximum efficiency in a much shorter time for filtration. This prevents items from warming up & redissolving and / or not securing. Hochstrom dual plate kit is the last filter you will ever need to buy. Summit Research, only the best.   https://youtu.be/_F65D3Skmj0 100% made in USA.  100% Billet machined for exacting fit.
  • The Separatory Funnel 6 Liter comes with a Sep Funnel Cap 45 that has improved recessed port for increased velocity when self mixing. The application, with vacuum, will launch the washing solution into the loaded solution and properly mix them without ever having to remove the funnel from the stand. The PTFE flow control valve (stopcock) is equipped with GL18 for adequate flow and accurate shutoff. Threaded 45/50 port out the top for Rodaviss. High temp PTFE GL connectors, rodaviss and cap all included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve whether you are water washing or terpene extracting and everything in between. Stands, clamps & supports not included.
       
    Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Separatory Funnel 6 Liter
  • Chromatography Column 3x24 (inches) with coarse/fine mixed frit. Heavy wall thickness of 3mm. Comes with Rodaviss connection and 45/50 Chroma Cap (GL14 feed/vacuum port). The drain has a PTFE stopcock to GL18. All GLs are included. Chroma Cap has elongated recessed port with diffuser. This directs fluid spray against walls to gently fill the column and protect media from movement. All of our chromatography columns now have option to add an Ultra Sensitive Fraction Finder! To comply with warranty, Summit requires this chromatography column to be supported by a chain clamp and a top mounted cork clamp. Summit recommends applying a thin rubber strip (the length of the chains contact) under the chain clamp (not shown) to maximize grip. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment you deserve for all your chromatography and CRC proccess's. Lab stands and clamps not included.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Chromatography Column 3x24
  • The Hochstrom Filter™ is the industries highest free flowing filter with Lifetime warranty and the LAST FILTRATION APPARATUS YOU WILL EVER BUY. No more glass, no more broken or chipped frits and absolutely no warped or low end plastic/ceramic units. 100% made in the USA and built to outperform anything on the market. Comes with dual O-ring seals that stay lubricated for smoothly securing the papers. With aerospace grade parts, this patented filter system has the highest flow on the market with ring seal technology. This is absolutely no joke when we say, this is the last buchner filter you will ever buy, capable of speeds unprecedented for its size. This filter comes with bottom (male thread) and 1/4 barb nipple, stainless mesh, stainless ring, viton O-rings (2) and tall tube (female thread). PDF Diagram Various micron sizes of Hochstrom papers: Hochstrom Stage 1 Paper Hochstrom Stage 2 Paper Hochstrom Stage 3 Paper Hochstrom Paper Package
  • Chromatography Column 4x36 (inches) with coarse/fine mixed frit. Heavy wall thickness of 3mm. Comes with Rodaviss connection and 45/50 Chroma Cap (GL14 feed/vacuum port). The drain has a PTFE stopcock to GL18. All GLs are included. Chroma Cap has elongated recessed port with diffuser. This directs fluid spray against walls to gently fill the column and protect media from movement. All of our chromatography columns now have option to add an Ultra Sensitive Fraction Finder! To comply with warranty, Summit requires this chromatography column to be supported by 2 chain clamps and a top mounted cork clamp. Summit recommends applying a thin rubber strip (the length of the chains contact) under the chain clamps (not shown) to maximize grip. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment you deserve for all your chromatography and CRC proccess's. Lab stands and clamps not included.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Chromatography Column 4x36
  • The Filter Bottle 20 Liter is genuine thick Schott glass media. We spared no cost to have our shop mount the bottle on a lathe and remove the bung section, replacing it with a Rodaviss female end. These flawless HEAVY DUTY glass filtration bottles are one of kind and come with Rodaviss wet-seal parts, Filter Bottle Top and High Temp PTFE GL14 connections. THIS ITEM DOES NOT HAVE A WARRANTY AND SHOULD BE TREATED WITH CARE ON A RUBBER MAT, WITHOUT OVER TIGHTENING THE TOP. RETURNS FOR DAMAGED BOTTLES WILL BE REFUSED UNCONDITIONALLY. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve for your filtration process's.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Filter Bottle 20 Liter
  • Chromatography Column 4x48 (inches) with coarse/fine mixed frit. Heavy wall thickness of 3mm. Comes with Rodaviss connection and 45/50 Chroma Cap (GL14 feed/vacuum port). The drain has a PTFE stopcock to GL18. All GLs are included. Chroma Cap has elongated recessed port with diffuser. This directs fluid spray against walls to gently fill the column and protect media from movement. All of our chromatography columns now have option to add an Ultra Sensitive Fraction Finder! To comply with warranty, Summit requires this chromatography column to be supported by 2 chain clamps and a top mounted cork clamp. Summit recommends applying a thin rubber strip (the length of the chains contact) under the chain clamps (not shown) to maximize grip. For this larger size column, Summit requires applying weight to the stand base such as a sand bag or something equivalent of 50 lbs+ (something to offset the weight of your fluids) As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment you deserve for all your chromatography and CRC proccess's.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Chromatography Column 4x48
  • Canna Bleach is a blended T-41 media with a sitting pH of 2-3. Acid activated bleaching clay that, when used, 5-30% in your boiling flask will achieve Delta 8. Used during oil purification, distillation prep, pesticide removal and odor removal. 44 lbs (20kg). sds  
  • Sale!

    Chromatography Column 6×48

    $1,699.99
    Chromatography Column 6x48 (inches) with coarse/fine mixed frit and heavy wall thickness of 3mm. Comes with Rodaviss connection and 45/50 Chroma Cap (GL14 feed/vacuum port). The drain has a PTFE stopcock to GL18. All GLs are included. Chroma Cap has elongated recessed port with diffuser. This directs fluid spray against walls to gently fill the column and protect media from movement. All of our chromatography columns now have option to add an Ultra Sensitive Fraction Finder! Please use this column at your own risk! In addition to lab stands, it is recommended that you secure the lab stands to a wall or sturdy foundation while also using sandbags. This column will surpass 100+ lbs of weight holding full fluid. Please make sure you are offsetting the weight of your fluids. Summit requires this chromatography column to be supported by 3 chain clamps and a top mounted cork clamp. Summit recommends applying a thin rubber strip (the length of the chains contact) under the chain clamps (not included) to maximize grip. This column may slip though clamps if not properly bottom supported. Recommended (yet again), to have a lab tripod base (use rubber stripping here as well) or circle clamp about 5" diameter (not included)(last picture). The 6x48 Chromatography Column has no warranty. Stands , clamps and sandbags not included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment you deserve for all your chromatography and CRC proccess's.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Chromatography Column 6x48
  • The Hochstrom High Flow Filter is the fastest unit on the market. It’s unique design allows it to operate under half vacuum pressure for full flow. Our peers & customers have reported the high flow surface area to be equivalent to a 18-24″ table-top unit. These units have a huge basin, but small holes, really preventing it from being efficient for it’s size. A table top or small buchner filtration unit will have flow issues due to the solution warming up & redissolving past the filtration medium. You also get the fluid rushing around the filter media as well as a large surface area for liquids to warm up. We have achieved maximum efficiency in a much shorter time for filtration. This prevents items from warming up & redissolving and / or not securing. Hochstrom filter is the last filter you will ever need to buy. Summit Research, only the best. 1x Hochstrom Filtration Package Stage 1 - 1000pcs of 20u chemical duty papers. Stage 2 - 1000pcs of 8u chemical duty papers. Stage 3 - 500pcs of sub 1u chemical duty 100% borosilicate papers(no chemical binder grade AE). All papers made in USA with no questionable composition, and no import junk. Straight up, best high flow papers you’ll ever use.

    Filtration Package

    Summit Research offers a filtration package that includes essential components for filtration : https://youtu.be/_F65D3Skmj0
  • Chroma Column FF 6x48 with coarse/fine mixed frit and heavy wall thickness of 3mm. Special design allows for #29 Fraction Finder that permits you to check your fraction and watch your progression. Attach a FF between the frit and the stopcock area. Comes with rodaviss , GL18 and #45 Chroma Cap. Fraction Finder not included. All of our chromatography columns now have option to add an Ultra Sensitive Fraction Finder! Please use this column at your own risk! In addition to lab stands, it is recommended that you secure the lab stands to a wall or sturdy foundation while also using sandbags. This column will surpass 100+ lbs of weight holding full fluid. Please make sure you are offsetting the weight of your fluids. Summit requires this chromatography column to be supported by 3 chain clamps and a top mounted cork clamp. Summit recommends applying a thin rubber strip (the length of the chains contact) under the chain clamps (not included) to maximize grip. This column may slip though clamps if not properly bottom supported. Recommended (yet again), to have a lab tripod base (use rubber stripping here as well) or a circular clamp about 5" diameter (not included)(last picture). The Chroma Column FF 6x48 has no warranty. https://www.instagram.com/p/B5Lv5CzBAS-/ As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment you deserve for all your chromatography and CRC proccess's. Stands, clamps, sandbag and Fraction Finder are not included.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Chroma Column FF 6x48
  • Summit Research offers a 2x Hochstrom Filtration Package that includes essential components for filtration : The Hochstrom High Flow Filter is the fastest unit on the market. It’s unique design allows it to operate under half vacuum pressure for full flow. Our peers & customers have reported the high flow surface area to be equivalent to a 18-24″ table-top unit. These units have a huge basin, but small holes, really preventing it from being efficient for it’s size. A table top or small buchner filtration unit will have flow issues due to the solution warming up and redissolving past the filtration medium. You also get the fluid rushing around the filter media as well as a large surface area for liquids to warm up. We have achieved maximum efficiency in a much shorter time for filtration. This prevents items from warming up and redissolving and/or not securing. The Hochstrom filter™ is the last filter you will ever need to buy. Summit Research, only the best. 2x Hochstrom Filtration Package. The 20L Filter Bottle is another original Summit Research product, going above and beyond to deliver a modified and custom filtration bottle. We chose to use genuine Schott media bottles. Had our shop mount the bottle on a lathe and remove the bung section while replacing it with a rodaviss female end. Summit have the highest quality modular caps custom made with male rodaviss joints. These flawless HEAVY DUTY glass filtration bottles are one of kind and found only at Summit. Accept no imitations, comes with rodaviss wet-seal parts and GL14 connections. Stage 1 - 1000pcs of 20u chemical duty papers. Stage 2 - 1000pcs of 8u chemical duty papers. Stage 3 - 500pcs of sub 1u chemical duty 100% borosilicate papers(no chemical binder grade AE). All papers made in USA with no questionable composition, and no import junk. Straight up, best high flow papers you’ll ever use.   https://youtu.be/_F65D3Skmj0   Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. 2x Hochstrom Filtration Package
  • Summit 4x48 Filter Column Complete comes with 2 stainless columns and complete rack and pump. 2 sets of sintered discs (16 total) (varying sizes) included. Swagelok valves. Stainless steel. Made in USA. Call us for more columns and fill your rack! Filter Column Complete
  • Summit Research offers a filtration package that includes essential components for filtration :

    Hochstrom Filter ™

    The Hochstrom High Flow Filter is the fastest unit on the market. It’s unique design allows it to operate under half vacuum pressure for full flow. Our peers & customers have reported the high flow surface area to be equivalent to a 18-24″ table-top unit. These units have a huge basin, but small holes, really preventing it from being efficient for it’s size. A table top or small buchner filtration unit will have flow issues due to the solution warming up and redissolving past the filtration medium. You also get the fluid rushing around the filter media as well as a large surface area for liquids to warm up. We have achieved maximum efficiency in a much shorter time for filtration. This prevents items from warming up and redissolving and/or not securing. The Hochstrom filter is the last filter you will ever need to buy. Summit Research, only the best. 2x Hochstrom + 1x PIG Filtration Package.

    20L Filter Bottle

    The 20L Filter Bottle is another original Summit Research product, going above and beyond to deliver a modified and custom filtration bottle. We chose to use genuine Schott media bottles. Had our shop mount the bottle on a lathe and remove the bung section while replacing it with a rodaviss female end. Summit have the highest quality modular caps custom made with male rodaviss joints. These flawless HEAVY DUTY glass filtration bottles are one of kind and found only at Summit. Accept no imitations, comes with rodaviss wet-seal parts and GL14 connections.

    High Flow Paper for Hochstrom

    Stage 1 - 1000pcs of 20u chemical duty papers. Stage 2 - 1000pcs of 8u chemical duty papers. Stage 3 - 500pcs of sub 1u chemical duty 100% borosilicate papers(no chemical binder grade AE). All papers made in USA with no questionable composition, and no import junk. Straight up, best high flow papers you’ll ever use.

    PIG Filter

    This patented made in USA (pressurized inert gas) PIG Filtration System eats material. At an idle flow of 500 gallons per hour under winterization temperatures reported speeds exceeding 8 gallons per minute of filtration power. We are the Sole distributor of this product in our industry. Do not forget your PIG papers. Summit strives to bring new things to market and ensure the needs are met. https://youtu.be/_F65D3Skmj0 https://youtu.be/JWwV-icP4Dk   Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. 2x Hochstrom + 1x PIG Filtration Package
  • Summit Research Tech offers a 4x Hochstrom filtration package that includes essential components for filtration :

    Hochstrom Filter ™

    The Hochstrom High Flow Filter is the fastest unit on the market. It’s unique design allows it to operate under half vacuum pressure for full flow. Our peers & customers have reported the high flow surface area to be equivalent to a 18-24″ table-top unit. These units have a huge basin, but small holes, really preventing it from being efficient for it’s size. A table top or small buchner filtration unit will have flow issues due to the solution warming up and redissolving past the filtration medium. You also get the fluid rushing around the filter media as well as a large surface area for liquids to warm up. We have achieved maximum efficiency in a much shorter time for filtration. This prevents items from warming up and redissolving and/or not securing. The Hochstrom filter is the last filter you will ever need to buy. Summit Research, only the best. 4x Hochstrom + 1x PIG Filtration Package.

    High Flow Paper for Hochstrom

    Stage 1 - 1000pcs of 20u chemical duty papers. Stage 2 - 1000pcs of 8u chemical duty papers. Stage 3 - 500pcs of sub 1u chemical duty 100% borosilicate papers(no chemical binder grade AE). All papers made in USA with no questionable composition, and no import junk. Straight up, best high flow papers you’ll ever use.

    20L Filter Bottle

    The 20L Filter Bottle is another original Summit Research product, going above and beyond to deliver a modified and custom filtration bottle. We chose to use genuine Schott media bottles. Had our shop mount the bottle on a lathe and remove the bung section while replacing it with a rodaviss female end. Summit have the highest quality modular caps custom made with male rodaviss joints. These flawless HEAVY DUTY glass filtration bottles are one of kind and found only at Summit. Accept no imitations, comes with rodaviss wet-seal parts and GL14 connections.

    PIG Filter

    This patented made in USA (pressurized inert gas) PIG Filtration System eats material. At an idle flow of 500 gallons per hour under winterization temperatures reported speeds exceeding 8 gallons per minute of filtration power. We are the Sole distributor of this product in our industry. Summit strives to bring new things to market and ensure the needs are met. https://youtu.be/_F65D3Skmj0   https://youtu.be/JWwV-icP4Dk   Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. 4x Hochstrom + 1x PIG Filtration Package