-
When the going gets tough, you can't ever be too safe! A triple coil intermediate trap with female 34/45 inlet and male outlet. This trapping mechanism is used as a laminar path connection recommended for larger short path distillation setups (22-50L) leading into dual cold traps. Heavy wall and joint thickness. Upgraded GL18 connections prevent barb breakage and mass body failure from stress of removing hoses. Extreme duty capacity and redesigned custom sized parallel flow coils that supply you with unmatched cooling. Collection flask port 45/50. Comes complete with: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Cold Trap 3 Shorty
-
Liquid Temp Control Key 34/45 is a short path distillation head key that is used to generate a localized cold/hot surface. The temperature achieved reduces or enlarges the quantity of volatile material exhausted into the air. This premium Schott glass 34mm plug is 8.5 inch overall length and 4.5 inch from the bottom of the frosted taper with the tip being a small condenser coil. High Temp GL14s included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Liquid Temp Control Key 34/45
-
The Valved Laminar Path 34 allows you to isolate your joint with a PTFE threaded valve. Enables you to swap out your receiving flask without loosing vacuum. With this option, simply lower the valve and unscrew the GL cap to release the vacuum to change your flask. Comes complete with 24/40 Stopper, all necessary keck clips, (3) GL14s (1 cap) and choice of #24/40 KF25 adapter. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Valved Laminar Path 34
-
The Valved Laminar Path 29 allows you to isolate your joint with a PTFE threaded valve. Enables you to swap out your receiving flask without loosing vacuum. With this option, simply lower the valve and unscrew the GL cap to release the vacuum to change your flask. Comes complete with 24/40 Stopper, all necessary keck clips, (3) GL14s (1 cap) and choice of #24/40 KF25 adapter. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Valved Laminar Path 29
-
Fits Size 29 or 34 Fraction Finder Sensor (drop down menu) Details:
- Goes in-line between the condenser & collection flask, allowing you to use the Fraction Finder in a new location and still run a hot condenser.
- High temperatures can be problematic for our sensor; this relocates where Fraction Finder could be positioned.
- Watch this video to see how it works.
-
$21,995.00
Polyscience Heavy Duty 10HP 3 Phase Chiller will handle different tasks - dual 50L roto rating. When precision liquid cooling matters, go with Polyscience cooling solutions.- DuraChill® Chillers 2HP and up are not available outside of the United States
- High capacity cooling for reactors
- Displays temperature and pressure or flow rate simultaneously
- User-adjustable temperature, pressure, and flow rate alarms
- Simple operation and maintenance
- Wide variety of options available
-
$21,995.00
Polyscience 5HP Heavy Duty 3 Phase Chiller will handle different tasks - 50L roto rating. When precision liquid cooling matters, go with Polyscience cooling solutions.- DuraChill® Chillers 2HP and up are not available outside of the United States
- High capacity cooling for plasma torch cutting, machine tool hydraulics, high powered lasers, and other high heat generating processes and equipment
- Displays temperature and pressure or flow rate simultaneously
- User-adjustable temperature, pressure, and flow rate alarms
- Simple operation and maintenance
- Wide variety of options available
-
$17,995.00
Polyscience 8HP Heavy Duty Air Cooled 3 Phase Chiller will handle different tasks - 50L roto rating. When precision liquid cooling matters, go with Polyscience cooling solutions.- DuraChill® Chillers 2HP and up are not available outside of the United States
- High capacity cooling for plasma torch cutting, machine tool hydraulics, high powered lasers, and other high heat generating processes and equipment
- Displays temperature and pressure or flow rate simultaneously
- User-adjustable temperature, pressure, and flow rate alarms
- Simple operation and maintenance
- Wide variety of options available
-
$14,285.00
Polyscience 3HP Heavy Duty Durachill will handle numerous tasks. Air cooled with simple operation and maintenance. When precision liquid cooling matters, go with Polyscience cooling solutions.- DuraChill® Chillers 2HP and up are not available outside of the United States
- High capacity cooling for plasma torch cutting, machine tool hydraulics, high powered lasers, and other high heat generating processes and equipment
- Displays temperature and pressure or flow rate simultaneously
- User-adjustable temperature, pressure, and flow rate alarms
- Simple operation and maintenance
- Wide variety of options available
-
Laminar Coil-less 34 is a shorter, more compact short path distillation arm which allows for higher temperatures in the vapor bypass. A true laminar with less turbulence. Comes with #24 glass stopper and choice of #24/40 KF25 adapter. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Laminar Coil-less 34
-
Laminar Coil-less 29 is a shorter, more compact short path distillation arm which allows for higher temperatures in the vapor bypass. A true laminar with less turbulence. Comes with #24 glass stopper and choice of #24/40 KF25 adapter. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Laminar Coil-less 29
-
$17,500.00
A BINDER safety vacuum drying oven ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber of the VDL safety vacuum drying oven is designed according to ATEX guidelines 2014/34/EU Ex II 3/-G Ex h IIB T1-T3 Gc X.Benefits
Important characteristics
Performance Data Temperature Heating-up time to 100 °C [min] 95 Temperature fluctuation [± K] 0.1 Temperature range 15 °C above ambient temperature to [°C] 200 Temperature variation at 100 °C [± K] 3.5 Vacuum Data Leak rate [bar/h] 0.01 Permitted end vacuum [mbar] 0.01 Electrical data Nominal power [kW] 1.9 Phase (Nominal voltage) 1~ Power frequency [Hz] 50/60 Rated Voltage [V] 230 Unit fuse [A] 10 Connections Compressed air connection for pressure-encapsulation 8 mm Inert gas connection with flow limiter (RP") 3/8 Measuring access port with small flange [DN mm] 16 Vacuum connection with small flange [DN mm] 16 Housing dimensions not incl. fittings and connections Depth net [in] 26.4 Height net [in] 35.46 Width net [in] 29.16 Internal Dimensions Depth [in] 18.12 Height [in] 19.94 Width [in] 19.94 Measures Interior volume [cu.ft.] 4.1 Load per rack [lbs] 44 Net weight of the unit (empty) [lbs] 337 Permitted load [lbs] 143 Viewing window height [in] 16.27 Viewing window width [in] 17.97 Wall clearance back [in] 3.94 Wall clearance sidewise [in] 5.32 Fixtures Number of shelves (std./max.) 2/6 Further information (Data Sheets, Operating Manuals and Technical Drawings) can be downloaded from BINDER. A Basic vacuum oven diagram can be seen/downloaded here:-
All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
To purchase, please contact Summit Research at 831-226-2948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing.
-