usa made

  • Premium Schott glass 45/50 well stopper. 4.75 inch length from bottom of the frosted taper. 9.5 inch overall length. Allows for accurate thermometer readings in the head. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Well Stopper 45/50
  • Premium Schott glass 34/45 plug. 7.75 inch overall length thermowell. 3 inch length from bottom of the frosted taper. Allows for accurate thermometer readings in the head while allowing zero rejection compared to a key with bands. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Well Stopper 34/45
  • Sale!

    Well Stopper 24/40

    $39.99
    Premium Schott glass 24/40 plug. 5.5 inch overall length thermowell. 2 inch length from bottom of the frosted taper. Allows for accurate thermometer readings in the head. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process.         Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Well Stopper 24/40
  • Valved Laminar Path 34

    From: $1,024.99
    The Valved Laminar Path 34 allows you to isolate your joint with a PTFE threaded valve. Enables you to swap out your receiving flask without loosing vacuum. With this option, simply lower the valve and unscrew the GL cap to release the vacuum to change your flask. Comes complete with 24/40 Stopper, all necessary keck clips, (3) GL14s (1 cap) and choice of #24/40 KF25 adapter. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Valved Laminar Path 34
  • The Valved Laminar Path 29 allows you to isolate your joint with a PTFE threaded valve. Enables you to swap out your receiving flask without loosing vacuum. With this option, simply lower the valve and unscrew the GL cap to release the vacuum to change your flask. Comes complete with 24/40 Stopper, all necessary keck clips, (3) GL14s (1 cap) and choice of #24/40 KF25 adapter. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Valved Laminar Path 29
  • The Valved Coil-less Laminar 34 allows you to isolate your joint with a PTFE threaded valve. Enables you to swap out your receiving flask without loosing vacuum. With this option, simply lower the valve and unscrew the GL cap to release the vacuum to change your flask. Comes complete with 24/40 Stopper, all necessary keck clips, GL14 cap and choice of #24/40 KF25 adapter. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Valved Coil-less Laminar 34
  • The Valved Coil-less Laminar 29 allows you to isolate your joint with a PTFE threaded valve. Enables you to swap out your receiving flask without loosing vacuum. With this option, simply lower the valve and unscrew the GL cap to release the vacuum to change your flask. Comes complete with 24/40 Stopper, all necessary keck clips, GL14 cap and choice of #24/40 KF25 adapter. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Valved Coil-less Laminar 29
  • First of its kind, innovation and performance meet the future of distillation. The Ultra Short Path Distillation Micro Head (previously SPD-7.1) is a fascinating technology inspired by an ultra low temperature process. The Summit research SPD-7.1 is a horizontal head designed to fully refine products at a low temperature; preferred material required should be refined previously, or physically refined through all filtration and washing/chroma processes prior to running through this system. Material must be completely dried and full vacuum cannot be engaged if material is wet. Do not attempt to load green/black crude material. This system requires much more vacuum requirement so please keep in mind the 22 liter system takes a diffusion, and the 5 liter system can use dual e2m28/30. With a high flow dual condenser coil to GL18 adapters, the temps are dialed in throughout this horizontal head. Big bore 45/50 inlet and outlet with a traditional 29/42 discharge to flask. Wait, there's more! This head acts as a large swing arm, so you can swing and engage the flask to your targeted fraction. See the SPD7 in action (pt1): Instagram Demo instagram logo See the SPD7 in action (pt2): Instagram Demo instagram logo Head, KF25 adapter and GL18s (2) included. Glassware (boiling flask & cold trap) exclusive to this ultra short path head: For a complete look at SPD-7.1 Micro USPD setup: As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your ultra short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Ultra Short Path Distillation Micro Head
  • First of its kind, innovation and performance meet the future of distillation. The Ultra Short Path Distillation Head (previously SPD-7) is a fascinating technology inspired by an ultra low temperature process. The Summit research SPD-7 is a horizontal head designed to fully refine products at a low temperature; preferred material required should be refined previously, or physically refined through all filtration and washing/chroma processes prior to running through this system. Material must be completely dried and full vacuum cannot be engaged if material is wet. Do not attempt to load green/black crude material. This system requires much more vacuum requirement so please keep in mind the 22 liter system takes a diffusion, and the 5 liter system can use dual e2m28/30. With a high flow triple condenser coil to GL18 adapters, the temps are dialed in throughout this horizontal head. Big bore 55/50 inlet and outlet with a traditional 29/42 discharge to flask. Wait, there's more! This head acts as a large swing arm, so you can swing and engage the flask to your targeted fraction. See the SPD7 in action (pt1): Instagram Demo instagram logo See the SPD7 in action (pt2): Instagram Demo instagram logo Head, KF25 adapter and GL18s (2) included. Glassware (boiling flask & cold trap) exclusive to this ultra short path head: Here is a complete look at the SPD-7 USPD setup. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your ultra short path distillation process.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Ultra Short Path Distillation Head
  • Sale!
    Thermometer Adapter 34 will allow a thermoprobe to submerge in your boiling flask's liquid. 34/45 Adapter has a small viton o-ring inside a PTFE cap for a secure fit. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Also available in Thermometer Adapter 24 Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Thermometer Adapter 34
  • Thermometer Adapter 24 will allow a thermoprobe to submerge in your boiling flask's liquid. 24/40 Adapter has a small viton o-ring inside a PTFE cap for a secure fit. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Also available in Thermometer Adapter 34 Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Thermometer Adapter 24
  • Sale!
    24/40 Continuous oil/water separator for terpene extraction. Isolates oil both lighter and heavier than water. Comes equipped with PTFE flow control valve (stopcock). For many different seperations. Find similar and corresponding parts in our Terpene Glassware section. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Terpene Oil/Water Separator
  • Sale!

    Terpene Head

    $94.99
    Summit Research custom made 45 to 24 high friction terpene head is the ultimate steam distillation condenser. This head is excellent for low vacuum/inert gas cfm condensing from the initial pathway. A first phase head that removes the bulk of the energy prior, to a more efficient condenser, like a graham unit. This prevents spitting of a second condenser and allows the turbulence to convert to a steady stream into second condenser. GL14 adapters (2) and keck clip included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Terpene Head
  • Sale!
    24/40 Connections top and bottom with (3) GL14s included. 24mm Terpene graham condenser column for terpene extractions. Condenser section is 12" tall while combined unit is 19" tall. Keck clips included (2). Find similar and corresponding parts in our Terpene Glassware section. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Terpene Graham Condenser
  • Sale!

    Terpene Distillation Kit

    $1,499.99
    Rock bottom SALE while supplies last. Please call us with any further questions. QUALIFIES FOR FREE SHIPPING This is a unique and very powerful organic Terpene Distillation Kit. It can also be used with organic solvents for a cold boil, and inert gas flooding for increased speeds and efficiency. Extraction kit comes with: (1) 2L Digital Mantle (pictured) (Power supply: 220v/50Hz; Heating power: 530W; Maximum temperature: 380 ° C;Stirring speed: 60 ~ 2300 rpm, Motor power: 40W) Thermo Probe included. (1) Boiling Flask 2L-3N-34 (2 neck pictured, you will get a 3 neck) (1) Thermometer Adapter 24 (1) Terpene Columns (1) Short Draw Terpene Head (1) Graham Condenser (1) Oil Water Separator (1) Separatory Funnel 1 Liter (2) Receiving Flask 24/40 250ml (2) Receiving Flask 24/40 1 Liter (1) Stopper 24/40 (2) Keck Clip 24/40 (6) GL14 Adapters (1) PTFE Triangle Pill 14×24mm (1) PTFE Egg Pill 10x20mm Does not include hoses, stands, clamps. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Terpene Distillation Kit
  • Sale!

    Terpene Column

    $119.99
    Terpene Column Glass column with perforated disc, not fritted. Base inlet 34/45 and 45/50 out the top. Used for high vapor flow in laminar pathway steam distillation of terpenes and other natural essences. Find similar and corresponding parts in our Terpene Glassware section. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Terpene Column
  • The Swing Arm Single Port 34 allows you to swing down for your targeted fraction. That's it. No vacuum break, no changing flasks. 34/45 Throughout with 29/42 discharge. Keck Clips included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Swing arm in use at the lab: Instagram Demo instagram logo     Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Swing Arm Single Port 34
  • The Swing Arm Single Port 29 allows you to swing down for your targeted fraction. That's it. No vacuum break, no changing flasks. All ports 29/42. GL14s and Keck Clips included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Swing arm in use at the lab: Instagram Demo instagram logo Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Swing Arm Single Port 29
  • Swing Arm Kit 34

    From: $517.75
    Swing Arm Kit 34 makes short path distillation easier. Swing down for your targeted fraction. That's it. No vacuum break, no changing flasks. Available in single or dual discharge,  in regular or jacketed and option of condenser. Glassware used for maximum efficiency distillation. Comes with: Shown below are the options you have to make this kit. Links are provided for reference, please use the drop down menus to make your selections.
    As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Discounts applied when purchasing this kit. Swing arm in use at the lab: Instagram Demo instagram logo Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Swing Arm Kit 34
  • Swing Arm Kit 29

    From: $451.25
    Swing Arm Kit 29 makes short path distillation easier. Swing down for your targeted fraction. That's it. No vacuum break, no changing flasks. Available in single or dual discharge,  in regular or jacketed and option of condenser. Glassware used for maximum efficiency distillation. Comes with: Shown below are the options you have to make this kit. Links are provided for reference, please use the drop down menus to make your selections.
    As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Discounts applied when purchasing this kit. Swing arm in use at the lab: Instagram Demo instagram logo Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Swing Arm Kit 29
  • The Swing Arm Jacketed Dual Port 34 allows you to swing down for your targeted fraction. That's it. No vacuum break, no changing flasks. 34/45 Throughout. Discharge ports are 29/42. GL14s and Keck Clips included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Swing arm in use at the lab: Instagram Demo instagram logo     Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Swing Arm Jacketed Dual Port 34
  • The Swing Arm Jacketed Dual Port 29 allows you to swing down for your targeted fraction. That's it. No vacuum break, no changing flasks. All ports 29/42. GL14s and Keck Clips included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Swing arm in use at the lab: Instagram Demo instagram logo     Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Swing Arm Jacketed Dual Port 29
  • The Swing Arm Jacketed 34 allows you to swing down for your targeted fraction. That's it. No vacuum break, no changing flasks. 34/45 Throughout. Discharge ports 29/42. GL14s and Keck Clips included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Swing arm in use at the lab: Instagram Demo instagram logo     Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Swing Arm Jacketed 34
  • The Swing Arm Jacketed 29 allows you to swing down for your targeted fraction. That's it. No vacuum break, no changing flasks. All ports 29/42. GL14s and Keck Clips included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Swing arm in use at the lab: Instagram Demo instagram logo     Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Swing Arm Jacketed 29
  • The Swing Arm Dual Port 34 allows you to swing down for your targeted fraction. That's it. No vacuum break, no changing flasks. 34/45 Throughout. Discharge ports are 29/42. GL14s and Keck Clips included. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Swing arm in use at the lab: Instagram Demo instagram logo     Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Swing Arm Dual Port 34
  • Swing Arm Dual Port 29. Swing down for your targeted fraction. That's it. No vacuum break, no changing flasks. All ports 29/42. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve to streamline your short path distillation process. Swing arm in use at the lab: Instagram Demo instagram logo Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Swing Arm Dual Port 29
  • The Swagelok DV-2 is a ball and needle 3/8 dual pump valve kit.  A high vacuum, 2 piece valve setup, rated for up to 8/9 scale. This item itself is a major tool in controlling vacuum or bleeding atmosphere into pump without risking any leak point. Swagelok is leading the industry in these types of valves. See for yourself: swagelok/valves
  • Sale!

    Stopper 34/45

    $29.99
    Schott Glass 34/45 stopper plug. 100% USA made. Don't accept the imitations.     Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Stopper 34/45
  • Schott Glass 24/40 stopper plug. 100% USA made. Don't accept the imitations.     Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Stopper 24/40
  • LN2 stainless steel inverted cup accelerator cold trap. Drier vacuum, lower vacuum and tighter fractions. Extremely compact with higher potency and an over all faster process. We cut the cold trap to show internals in slides 2 & 3. Born from the patented Summit inverse cup cold trap technology and delivered for liquid nitrogen usage. Stainless trap comes with sight glass (essentially a lock off cap) that can be removed and capped off. UPDATED: This SS trap now has 4.75 inch triclamp (4th slide) for many possibilities (liquid nitrogen, dry ice, immersion, sealed immersion, ect.) Included:
    • 2 inch triclamp Sight glass
    • 2 inch triclamp clamps and o-rings
    • 2 inch stainless flat cap
    • Unit installed with KF25 flanges in and out
    • Unit installed with 2 inch triclamp sight glass flange
    ss trap example Clamps, stands and glassware in example picture not included. 4.75 inch triclamp clamp and o-ring not included. Patented SS Cold Trap Accelerator available only here at Summit Research.