Fraction Finder

  • For short path heads with 24/40 connections to adapt the Size 29 Fraction Finder Sensor Fits Size 29 Fraction Finder Sensor Details: 24/40 male to 24/40 female extension with 28mm O.D. for the Size 29 Fraction Finder Sensor
  • Athena is available FREE with any Summit compatible device

    ATHENA Download ATHENA Software makes short path distillation easy. From data input and recipe import/export to tech support and system diagnose. Track all your Summit systems in one place efficiently and dynamically. Included highlighted features are:
    • Comprehensive Summit to customer tech support software with direct ability to see and diagnose any issues.
    • Open source sharing of recipes for any user to any user if desired.
    • Import export features for data and recipes.
    • Comprehensive no feature missed data logging.
    • Run start to finish fully encompassed fraction to run-time traceability.
    • Manual and automation mantle control and real time display with predictive logging.
    • Fraction Finder compatibility.
    • Apollo compatibility.
    • Techno Heat Mantle compatibility.
    • Complete ramping control with infinite sop management.
    • Sop manager compiles and creates active private resource for all users.
    • No network needed.
    Locally ran, requires three USB ports or a compatible USB hub.

    Call us 8312262948 for your individual product key.

    Easy step by step installation can be viewed on YouTube   Replacement USB cords are as follows for each device: Apollo Vacuum Controller Fraction Finder Techno Heat Mantle USB Hub  
  • Chroma Column FF 6x48 with coarse/fine mixed frit and heavy wall thickness of 3mm. Special design allows for #29 Fraction Finder that permits you to check your fraction and watch your progression. Attach a FF between the frit and the stopcock area. Comes with rodaviss , GL18 and #45 Chroma Cap. Fraction Finder not included. All of our chromatography columns now have option to add an Ultra Sensitive Fraction Finder! Please use this column at your own risk! In addition to lab stands, it is recommended that you secure the lab stands to a wall or sturdy foundation while also using sandbags. This column will surpass 100+ lbs of weight holding full fluid. Please make sure you are offsetting the weight of your fluids. Summit requires this chromatography column to be supported by 3 chain clamps and a top mounted cork clamp. Summit recommends applying a thin rubber strip (the length of the chains contact) under the chain clamps (not included) to maximize grip. This column may slip though clamps if not properly bottom supported. Recommended (yet again), to have a lab tripod base (use rubber stripping here as well) or a circular clamp about 5" diameter (not included)(last picture). The Chroma Column FF 6x48 has no warranty. https://www.instagram.com/p/B5Lv5CzBAS-/ As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment you deserve for all your chromatography and CRC proccess's. Stands, clamps, sandbag and Fraction Finder are not included.       Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Chroma Column FF 6x48
  • Fits Size 29 Fraction Finder Sensor Details:
    • Bundle that includes the Collection Jar Adapter and Collection Jar Mount
    • For use with Wiped Film Evaporation systems, such as Root Sciences/VTA, to enable collected distillate to flow through the Size 29 Fraction Finder Sensor
    • For use with Ball collection jar (not included)
     
  • The Extraction Finder is a real-time molecular monitoring system for botanical extraction, which is essential for consistently maximizing the amount of extracted compounds within a given plant material. This robust model will serve hydrocarbon and ethanol extractions. Not rated for use with C02 extractions. The robust housing, which fully encloses the molecular sensor, can be easily installed in-line in the extraction design on sanitary flange end clamps. A 30′ sensor cable feeds this information to a high-quality touch-screen, which displays real-time levels of Cannabinoids, Chlorophyll and Lipids. The Extraction Finder’s digital readout can be used to help operators learn about and dial-in their process, such as optimizing flow rate, solvent amount, filter efficiency, and general quality assurance and control. In the long run, this system will be your best friend in dialing-in the most effective standard operating procedures (SOPs). Extraction Sensor
    • Housed and enclosed by the Extraction Sensor Housing
    • Connects and transmits to the digital display via 30′ sensor cable
    • Plug and play – instantaneously analyzes the mixture flowing through the processing machine
    Extraction Sensor Housing
    • Attaches directly onto sanitary flange connections (1.5″ or 2″) at any point in your extraction line
    • Houses the sensor, fully enclosing it from hazardous environments
    • C1D1/D2 certification
    Extraction Digital Display
    • Tablet-sized display mounts directly onto a lab pole
    • Connects and interprets the wavelength information from the sensor
    • Touch-screen interface displays real-time molecular information about the contents of the extraction fluid throughout the process
    • Includes long wiring, allowing it to be placed away from C1D1/D2 area
    Key Software Features:
    • Molecular Selection – Select from a growing list of key molecules, including Cannabinoids, Chlorophyll, and Lipids; see full list here
    • Intensity Values – Track as molecular intensity levels increase and decrease throughout the process
    • Data Logging – Record and export run data for traceability
    • Software Updates – Upgrade to software releases easily from the field (extraction finder software)
    Specifications
    • Maximum Pressure: 240Psi
    • Temperature: -70°C(min); 150°C(max)
    • Mounting Plate: Available as an add-on
    • Product Dimensions: 6.79in(L) x 5.39in(W)
    • Wavelength of Excitation: 365 nm
    • Optical Detection Range: 3001000 nm
    • Lower Detection Limit: <1mg/mL (at a volume of 1 cubic centimeter of oil)
    • Resolution: Spectral resolution is 15 nm max
    • Flow Rate Limit: No flow rate limit

    Lack of objectivity during the extraction process

    The purpose of botanical extraction processes, regardless of solvent used, is essentially to introduce a solvent to the biomass that will bind to, strip, and help obtain as much of the desirable compounds as possible. However, extraction operators have no solid metric to base their success on, aside from color in sight glasses or laboratory testing. While observing color can be done in-line, it is a subjective metric at best. While lab results are an objective metric, it is nearly impossible to correlate in practice and can take days or even weeks to obtain after a run. While both of these are helpful techniques that should be utilized during the process, they should not be solely relied upon since they lack real-time objectivity. Subjective monitoring that is based on perception or guesswork is imprecise, inconsistent, and difficult to scale. What is the effect of this lack of molecular monitoring during extraction? Batches that are sub-optimally extracted, resulting in either low yields or potency, and even wasted solvents and time. Examples of Applications The most popular applications of the Extraction Finder are hydrocarbon and ethanol extraction. The system can be installed in-line on extractors where there are 1.5” or 2” sanitary flange connections. Multiple units can be placed at multiple points of the extraction design. Hydrocarbon extraction: The unit can be installed in-line between the material column and collection column. Pre-filtration or CRC, the unit’s live data can help you determine what flow rate optimizes both solvated mass & time. Post-filtration or CRC, it can confirm that Chlorophyll is not making it past the filter. Ethanol extraction: The unit can be installed in-line at the recirculation area. It can be used to determine solvent saturation by seeing when the solvent has absorbed the majority of Cannabinoids. The unit is so sensitive that it can even be helpful for confirmation of removal of molecules during a cleaning run.

    Included in this package:

    • Extraction Finder Display
    • Extraction Sensor Housing with ultra-sensitive sensor
    • Power Supply, with 10′ Extension
    • Sensor Cable, 30′
    • Pole-Mounting Bracket
    • User Manual
    • Warranty Card
    More videos and conversations on our YouTube and Instagram https://youtu.be/dS7qr2g1Q5o
  • Summit Research Fraction Finder figures out where components start and stop flowing to optimize separation. Making the SPD Process more precise and repeatable, Fraction Finding helps take the guess work out. Someone running a distillation can make better decisions if they knew exactly where they were in the distillation process. Scientists have developed expertise in this area to the point where they know what to expect. The Summit Research Fraction Finder does that for you and will be your best friend in short path distillation. Included with:
    • Standard sensor
    • Mounting hardware
    • Display screen
    • Light-blocking tape
    • Power Supply
    • Sensor Cable
    • User Manual and Quick Start Guide
    • 1-Year Warranty
    Through innovative live distillate monitoring, Fraction Finding can help increase potency on every distillation pass. Now, you can forget the old ways of relying on guesswork and eyesight, and instead, identify the contents of a flow through a glass tube in real time. Please contact Summit Research if you want to upgrade to the Ultra-Sensitive Fraction Finder. This new version can now be utilized on chromatography separations as well as your normal distillation processes. We now include FREE ATHENA SOFTWARE for download (Fraction Finder compatibility) More videos and conversations on our Instagram https://youtu.be/IPJVbMJlU_0

    Frequently Asked Questions

    Which fractions can the Fraction Finder detect? During short-path distillation, it can distinguish what is colloquially known as “Heads”, “Main Bodies”, and “Tails”. Click here for a list of molecules, such as Delta-9 and more. What units of measure does the Fraction Finder digital readout use?  The system uses Nanometers (nm) and Intensity (au). Can the Fraction Finder sensor fit on size 24 glass? If you have size 24 glass, order our 24/40 adapter, which can fit a size 29 sensor.  What heat can the Fraction Finder sensor handle? The Fraction Finder sensor can handle around 100 degrees Fahrenheit. If you plan to exceed these limits, order one of our Hot Tech Adapters. Does the Fraction Finder work the same as an HPLC? Both systems use spectroscopic analysis to identify chemicals. However, the type of spectroscopy that detection method and wavelength regime are different. The Fraction Finder operates uses fluorescence, whereas HPLCs utilize absorption.  
  • Fraction Finder Adapter allows for an Ultra-Sensitive Fraction Finder to be utilized on any chromatography unit. GL18 to size 34 glass to GL18. As always, Summit uses 100% best quality glass blanks that are THICKER and built BEYOND STANDARDS made right here in the USA. Our glassware is made specifically for efficiency and durability. Summit provides the quality of lab equipment that you deserve.       Fraction Finder and hosing not included. Summit recommends all users of any and all glassware to operate inside a ventilated fume hood with sufficient blast shields to prevent injury in case of fatigued glass failure. Summit is not responsible or liable for the result of any failures from use, and/or loss of subsequent hardware contamination/failure with or without the result of material loss or damaged caused to surroundings. By purchasing our premiere lines of laboratory glassware the user is responsible to operate in the recommended environment safely. We recommend all users to operate in a legal and licensed facility where safety is the number 1 goal. Fraction Finder Adapter  
  • The Fraction Finder Ultra Sensitive figures out where components start and stop flowing to optimize separation. Making the SPD Process more precise and repeatable, Fraction Finding helps take the guess work out. Someone running a distillation can make better decisions if they knew exactly where they were in the distillation process. Scientists have developed expertise in this area to the point where they know what to expect. The Summit Research Fraction Finder does that for you and will be your best friend in short path distillation. Included with:
    • Ultra Sensitive sensor
    • Mounting hardware
    • Display screen
    • Light-blocking tape
    • Power Supply
    • Sensor Cable
    • User Manual and Quick Start Guide
    • 1-Year Warranty
    Through innovative live distillate monitoring, Fraction Finding can help increase potency on every distillation pass. Now, you can forget the old ways of relying on guesswork and eyesight, and instead, identify the contents of a flow through a glass tube in real time. The Fraction Finder Ultra Sensitive package is unique in that - not only does it serve distillation and extraction processes - but also serves Chromatography, Conversion Reaction, and other processes that require more extreme detection. For certain processes, highly sensitive process monitoring is essential. Generally speaking, the more solvent involved in the process means the more sensitive the sensor needs to be. With that in mind, the ULTRA was created. If you have the original Fraction Finder, you have the option to upgrade to a standalone ULTRA Sensor for $1,350. Please call us for more details. Use this sensor on any chromatography column with the GL18 to #34 adapter. The Fraction Finder Sensor #34 consists of an optical light pulse and detector, acting as “the eyes” of the system. It wraps around a distillation/chromatography setup tube and connects to the Fraction Finder display to track important data on the process.
    • Fraction Finder optical sensor with ultra-sensitive detector
    • Magnetic locking mechanism
    • Anodized aluminum apertures
    • 90° strap rotation
    • Currently only available in size 34
    • Validated by Arometrix for use on distillation systems
    • Currently being tested on reverse-phase chromatography processes
    • Display and sight glass not included

    Information common with all Fraction Finder sensors

    These sensors are black for a reason:
    • Black absorbs all light while blocking out ambient light.
    • This leads to better signaling and the most valid data possible transmitting to the Fraction Finder display.
    • For example, a white sensor wouldn’t work because it would reflect the light into your glassware and into the sensor, harming the reading.
    Chemical Resistant
    • This reduces any degradation from solvents, crude oils, extracts, etc..
    • This protects the sensor and ensures that it lives to see an endless amount of runs.
    Thermo Resistant / Safety
    • The black coating we use on each sensor is a high temperature, thermal resistant coating, it can withstand temperatures well above anything you’d see in a distillation lab.
    • It’s nearly impossible to set one of our sensors on fire, the coating is almost completely fireproof!
    • This protects the user, the equipment, and (in worst case scenarios) the entire lab.
  • Fits Size 29 or 34 Fraction Finder Sensor (drop down menu) Details:
    • Goes in-line between the condenser & collection flask, allowing you to use the Fraction Finder in a new location and still run a hot condenser.
    • High temperatures can be problematic for our sensor; this relocates where Fraction Finder could be positioned.
    • Watch this video to see how it works.
    Sensor not included  
  • Sensor #29

    $1,919.99
    The Fraction Finder Sensor #29 consists of an optical light pulse and detector, acting as “the eyes” of the system. It wraps around a distillation set up condenser tube and connects to the Fraction Finder display to track important data on the distillation. These sensors are black for a reason:
    • Black absorbs all light while blocking out ambient light.
    • This leads to better signaling and the most valid data possible transmitting to the Fraction Finder display.
    • For example, a white sensor wouldn’t work because it would reflect the light into your glassware and into the sensor, harming the reading.
    Chemical Resistant
    • This reduces any degradation from solvents, crude oils, extracts, etc..
    • This protects the sensor and ensures that it lives to see an endless amount of runs.
    Thermo Resistant / Safety
    • The black coating we use on each sensor is a high temperature, thermal resistant coating, it can withstand temperatures well above anything you’d see in a distillation lab.
    • It’s nearly impossible to set one of our sensors on fire, the coating is almost completely fireproof!
    • This protects the user, the equipment, and (in worst case scenarios) the entire lab.
    Sensor only, monitor and accessories not included.
  • Sensor #34

    $2,094.99
    The Fraction Finder Sensor #34 consists of an optical light pulse and detector, acting as “the eyes” of the system. It wraps around a distillation set up condenser tube and connects to the Fraction Finder display to track important data on the distillation. These sensors are black for a reason:
    • Black absorbs all light while blocking out ambient light.
    • This leads to better signaling and the most valid data possible transmitting to the Fraction Finder display.
    • For example, a white sensor wouldn’t work because it would reflect the light into your glassware and into the sensor, harming the reading.
    Chemical Resistant
    • This reduces any degradation from solvents, crude oils, extracts, etc..
    • This protects the sensor and ensures that it lives to see an endless amount of runs.
    Thermo Resistant / Safety
    • The black coating we use on each sensor is a high temperature, thermal resistant coating, it can withstand temperatures well above anything you’d see in a distillation lab.
    • It’s nearly impossible to set one of our sensors on fire, the coating is almost completely fireproof!
    • This protects the user, the equipment, and (in worst case scenarios) the entire lab.
    Sensor only, monitor and accessories not included.
  • The Sensor Ultra Sensitive features the brand new, ultra-sensitive sensor. This package is unique in that - not only does it serve distillation and extraction processes - but also serves Chromatography, Conversion Reaction, and other processes that require more extreme detection. For certain processes, highly sensitive process monitoring is essential. Generally speaking, the more solvent involved in the process means the more sensitive the sensor needs to be. With that in mind, the ULTRA was created. If you are an existing customer, you have the option to upgrade to a standalone ULTRA Sensor for $1,350. Please call us for more details. Use this sensor on any chromatography column with the GL18 to #34 adapter. The Fraction Finder Sensor 34/45 consists of an optical light pulse and detector, acting as “the eyes” of the system. It wraps around a distillation/chromatography setup tube and connects to the Fraction Finder display to track important data on the process.
    • Fraction Finder optical sensor with ultra-sensitive detector
    • Magnetic locking mechanism
    • Anodized aluminum apertures
    • 90° strap rotation
    • Currently only available in size 34mm
    • Validated by Arometrix for use on distillation systems
    • Currently being tested on reverse-phase chromatography processes
    • Display and sight glass not included

    Information common with all Fraction Finder sensors

    These sensors are black for a reason:
    • Black absorbs all light while blocking out ambient light.
    • This leads to better signaling and the most valid data possible transmitting to the Fraction Finder display.
    • For example, a white sensor wouldn’t work because it would reflect the light into your glassware and into the sensor, harming the reading.
    Chemical Resistant
    • This reduces any degradation from solvents, crude oils, extracts, etc..
    • This protects the sensor and ensures that it lives to see an endless amount of runs.
    Thermo Resistant / Safety
    • The black coating we use on each sensor is a high temperature, thermal resistant coating, it can withstand temperatures well above anything you’d see in a distillation lab.
    • It’s nearly impossible to set one of our sensors on fire, the coating is almost completely fireproof!
    • This protects the user, the equipment, and (in worst case scenarios) the entire lab.
    Sensor only, monitor and accessories not included.
  • From: $8,450.00

    Interfaces any centrifuge extractor that doesn't require C1D2 (ethanol, heptane, methanol, etc.) with the size 34 Fraction Finder sensor.
    Sight Glass for Ethanol Extraction – includes shield and modified size 34 sensor
    • 1.5″ or 2" Sanitary flange sight glass with shield and a modified sensor (includes sensor pre-installed, evacuation/purge cycle, vacuum and pressure tested, sensor tested, and 10′ cable)
    • Fraction Finder sensor included and pre-installed
    • For use with an ethanol extractor
      To purchase, please contact Summit Research at 8312262948 or by eMail. Items ship 1-3 days after orders have been processed unless otherwise specified. Price does not include shipping and will be included in your final estimate before processing.
  • Fits Size 29 Fraction Finder Sensor Details:
    • 1L teardrop/recovery flask with Rodaviss 29/42 connection with extended neck with 28mm O.D.
     
  • Fits Size 29 Fraction Finder Sensor Details:
    • 29/42 Rodaviss male to female adapter with 28mm 1.5″ section for Size 29 Fraction Finder Sensor
    • 29/42 Rodaviss kit/smaller parts with cap, O-ring, and loosening ring